A proposed alternative to phase-space recycling using the adaptive kernel density estimator method

被引:4
作者
Tyagi, N
Martin, WR
Du, J
Bielajew, AF
Chetty, IJ [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[3] JD Power & Associates, Power Informat Network, Troy, MI 48098 USA
关键词
adaptive kernel density estimator; Monte Carlo; phase space; linac simulation;
D O I
10.1118/1.2163250
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have implemented a nonparametric density estimation technique, the adaptive kernel density estimator (AKDE), to generate additional phase space (PS) variables in the vicinity of simulated PS points in Monte Carlo linear accelerator simulation. The method involves the placement of kernels at simulated PS points that have a "window width" that depends on the density of simulated PS points. This method has been tested on known one-dimensional (I-D) and two-dimensional (2-D) probability density functions (PDFs) and has been used to sample (photons only) from PS files generated from accelerator simulations. The original simulated PS vector (x, y, u, v, E) was reduced to a rotationally invariant PS vector (r, theta, alpha, E) that takes advantage of the azimuthal symmetry (phi) above the collimating jaws. The new PS vector (r', theta', alpha', E) is sampled in the vicinity of the sampled PS vector (r, 0, a, E). The first step in assessing the accuracy of the method was a correlation analysis among the AKDE generated PS variables compared with correlations among the original PS variables. "In-air" particle fluence distributions between AKDE samples and the original PS distribution showed agreement within 2% (-8.8% to 6.8%) across the entire phase space plane. Central axis energy distributions and angular distributions agreed on average to within 1.5% (range=-1.5% to 6.6%) and 0.1% (range=0 to 3.0%), respectively. Dose profiles were calculated for field sizes 3 x 3 cm(2), 10 x 10 cm(2), and 30 x 30 cm(2) for AKDE and compared against calculations performed with PS recycling. AKDE calculated depth doses and profiles were within 2% and 2%/1 mm, respectively, of those computed using PS recycling. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:553 / 560
页数:8
相关论文
共 6 条
[1]   Photon beam relative dose validation of the DPM Monte Carlo code in lung-equivalent media [J].
Chetty, IJ ;
Charland, PM ;
Tyagi, N ;
McShan, DL ;
Fraass, BA ;
Bielajew, AF .
MEDICAL PHYSICS, 2003, 30 (04) :563-573
[2]  
DU J, 1996, T AM NUCL SOC, V74, P171
[3]  
ROGERS DWO, 2004, 509A NRC PIRS
[4]   DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations [J].
Sempau, J ;
Wilderman, SJ ;
Bielajew, AF .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) :2263-2291
[5]  
Silverman B. W, 1986, Monographs on Statistics and Applied Probability, DOI [DOI 10.2307/2347507, 10.1201/9781315140919]
[6]   History by history statistical estimators in the BEAM code system [J].
Walters, BRB ;
Kawrakow, I ;
Rogers, DWO .
MEDICAL PHYSICS, 2002, 29 (12) :2745-2752