A one step reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for detection of viral hemorrhagic septicaemia virus (VHS). A set of six primers were designed, based on the G-protein sequence of the VHS virus serotypes (He, Fl, 23.75, Klapmolle and Rindsholm). The assay was optimised to amplify VHS RNA by incubation at 63 degrees C for only 1 h, and required only a simple water bath or heating block to provide a constant temperature of 63 degrees C. RT-LAMP amplification products were detected by visual inspection using SYBR Green I stain and had a ladder-like appearance when electrophoresed on an agarose gel. The detection limit of the RT-LAMP assay was found to be similar to the commonly used RTPCR method: both methods detected VHS RNA at a dilution of 10(6). The assay was evaluated using clinical samples and the results indicated the suitability and simplicity of the test as a rapid, field diagnostic tool for VHS virus. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 213
页数:9
相关论文
共 41 条
[1]  
AHNE W, 1985, ZBL VET MED B, V32, P73
[2]  
AMOS KH, 1985, FISH HLTH SECTION, P114
[3]   DIFFERENTIAL-DIAGNOSIS OF FISH PATHOGENIC RHABDOVIRUSES BY REVERSE TRANSCRIPTASE-DEPENDENT POLYMERASE CHAIN-REACTION [J].
BRUCHHOF, B ;
MARQUARDT, O ;
ENZMANN, PJ .
JOURNAL OF VIROLOGICAL METHODS, 1995, 55 (01) :111-119
[4]   Rapid detection of a fish iridovirus using loop-mediated isothermal amplification (LAMP) [J].
Caipang, CMA ;
Haraguchi, I ;
Ohira, T ;
Hirono, I ;
Aoki, T .
JOURNAL OF VIROLOGICAL METHODS, 2004, 121 (02) :155-161
[5]  
EINERJENSEN K, 1995, VET RES, V26, P464
[6]  
Enzmann P. J., 1981, Developments in Biological Standardization, V49, P57
[7]  
Guillou JP, 1999, VET RES, V30, P49
[8]   A loop mediated isothermal amplification (LAMP) method for detection of infectious hematopoietic necrosis virus (IHNV) in rainbow trout (Oncorhynchus mykiss) [J].
Gunimaladevi, I ;
Kono, T ;
LaPatra, SE ;
Sakai, M .
ARCHIVES OF VIROLOGY, 2005, 150 (05) :899-909
[9]   Detection of koi herpesvirus in common carp, Cyprinus carpio L., by loop-mediated isothermal amplification [J].
Gunimaladevi, I ;
Kono, T ;
Venugopal, MN ;
Sakai, M .
JOURNAL OF FISH DISEASES, 2004, 27 (10) :583-589
[10]   Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M-avium, and M-intracellulare in sputum samples [J].
Iwamoto, T ;
Sonobe, T ;
Hayashi, K .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) :2616-2622