Automatic removal of eye movement and blink artifacts from EEG data using blind component separation

被引:416
作者
Joyce, CA
Gorodnitsky, IF
Kutas, M [1 ]
机构
[1] Univ Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Comp Sci, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Neurosci, La Jolla, CA 92093 USA
关键词
electroencephalogram; artifact; electrooculogram; automated; blind source separation; independent component analysis;
D O I
10.1111/j.1469-8986.2003.00141.x
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Signals from eye movements and blinks can be orders of magnitude larger than brain-generated electrical potentials and are one of the main sources of artifacts in electroencephalographic (EEG) data. Rejecting contaminated trials causes substantial data loss, and restricting eye movements/blinks limits the experimental designs possible and may. impact the cognitive processes under investigation. This article presents a method based on blind source separation (BSS) for automatic removal of electroocular artifacts from EEG data. BBS is a signal-processing methodology that. includes independent component analysis (ICA). In contrast to previously explored ICA-based methods for artifact removal, this method is automated. Moreover, the BSS algorithm described herein can isolate correlated electroocular components with a high degree of accuracy. Although the focus is on eliminating ocular artifacts in EEG data, the approach can be extended to other sources of EEG contamination such as cardiac signals, environmental noise, and electrode drift, and adapted for use with magnetoencephalographic (MEG) data, a magnetic correlate of EEG.
引用
收藏
页码:313 / 325
页数:13
相关论文
共 21 条
[1]   METHODOLOGICAL CONSIDERATIONS FOR THE EVALUATION OF SPATIOTEMPORAL SOURCE MODELS [J].
ACHIM, A ;
RICHER, F ;
STHILAIRE, JM .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1991, 79 (03) :227-240
[2]   A blind source separation technique using second-order statistics [J].
Belouchrani, A ;
AbedMeraim, K ;
Cardoso, JF ;
Moulines, E .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (02) :434-444
[3]  
Belouchrani A., 1993, P INT C DIG SIGN PRO, P346
[4]   DIPOLE MODELING OF EYE ACTIVITY AND ITS APPLICATION TO THE REMOVAL OF EYE ARTIFACTS FROM THE EEG AND MEG [J].
BERG, P ;
SCHERG, M .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 :49-54
[5]   A MULTIPLE SOURCE APPROACH TO THE CORRECTION OF EYE ARTIFACTS [J].
BERG, P ;
SCHERG, M .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 90 (03) :229-241
[6]   DIPOLE MODELS OF EYE-MOVEMENTS AND BLINKS [J].
BERG, P ;
SCHERG, M .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1991, 79 (01) :36-44
[7]   BLIND BEAMFORMING FOR NON-GAUSSIAN SIGNALS [J].
CARDOSO, JF ;
SOULOUMIAC, A .
IEE PROCEEDINGS-F RADAR AND SIGNAL PROCESSING, 1993, 140 (06) :362-370
[8]  
Delorme A., 2001, P 3 INT ICA C DEC 9
[9]  
GORODNITSKY IF, 2001, P 3 INT ICA C DEC 9
[10]   Dealing with artifacts: The EOG contamination of the event-related brain potential [J].
Gratton, G .