STIR vs. T1-weighted fat-suppressed gadolinium-enhanced MRI of bone marrow edema of the knee: Computer-assisted quantitative comparison and influence of injected contrast media volume and acquisition parameters

被引:52
作者
Mayerhoefer, ME
Breitenseher, MJ
Kramer, J
Aigner, N
Norden, C
Hofmann, S
机构
[1] Med Univ Vienna, Dept Radiol, Osteoradiol & Surg Radiol Sect, Vienna, Austria
[2] Walviertelklinikum Horn, Horn, Austria
[3] Inst CT & MRI Diagnost, Linz, Austria
[4] Orthopaed Hosp Vienna Speising, Orthopaed Dept 1, Vienna, Austria
[5] Schering AG, Clin Dev Cardiovasc, D-1000 Berlin, Germany
[6] LKH Stolzalpe, Dept Orthopaed, Stolzalpe, Austria
关键词
knee; MR; bone marrow; abnormalities; magnetic resonance (MR); inversion recovery; contrast enhancement; volume measurement;
D O I
10.1002/jmri.20439
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To compare short tau inversion recovery (STIR) and T1-weighted (T1w) gadolinium (Gd)-enhanced fat-suppressed MRI of bone marrow edema (BME) of the knee, and investigate the influence of injected contrast media volume and variation of major acquisition parameters on apparent BME volume and signal contrast. Materials and Methods: STIR and T1w Gd-enhanced fat-suppressed images were obtained from 30 patients with BME of the knee. Two groups of patients were examined with different MR scanners, acquisition parameters, and contrast media volumes. For both sequences, BME volume and signal contrast were assessed by computer-assisted quantification, and were compared through their arithmetic means and correlation coefficients (r(2)). The Injected contrast media volume was also correlated with BME volume and signal contrast differences between sequences. Results: A strong correlation between the STIR and Gd-enhanced T1w images was found for BME volume (r(2) = 0.96-0.99) and BME signal contrast (r(2) = 0.86-0.94). Despite the differences in MR acquisition parameters and Injected contrast media volume, both sequences depicted an almost identical BME volume in both groups. Contrast media volume showed a moderate correlation (r(2) = 0.40) with BME volume differences. Conclusion: STIR is the optimum method for deter-mining the size and signal contrast of BME. The injected contrast media volume appears to have only a limited influence on apparent BME volume.
引用
收藏
页码:788 / 793
页数:6
相关论文
共 13 条
[1]
Cohen L., 1982, STAT SOCIAL SCI
[2]
An update on the pathogenesis and epidemiology of osteoarthritis [J].
Felson, DT .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2004, 42 (01) :1-+
[3]
Volumetric analysis of osteonecrosis of the femur - Anatomical correlation using MRI [J].
Hernigou, P ;
Lambotte, JC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (05) :672-675
[4]
Painful bone marrow edema of the knee: differential diagnosis and therapeutic concepts [J].
Hofmann, S ;
Kramer, J ;
Vakil-Adli, A ;
Aigner, N ;
Breitenseher, M .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2004, 35 (03) :321-+
[5]
Hofmann S, 2003, ARTHROSKOPIE, V16, P88
[6]
QUANTIFYING THE EXTENT OF OSTEONECROSIS OF THE FEMORAL-HEAD - A NEW METHOD USING MRI [J].
KOO, KH ;
KIM, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (06) :875-880
[7]
MacDougall L, 1996, TOP MAGN RESON IMAG, V8, P44
[8]
Computer-assisted quantitative analysis of bone marrow edema of the knee: Initial experience with a new method [J].
Mayerhoefer, ME ;
Breitenseher, M ;
Hofmann, S ;
Aigner, N ;
Meizer, R ;
Siedentop, H ;
Kramer, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (06) :1399-1403
[9]
Shifting bone marrow edema of the knee [J].
Moosikasuwan, JB ;
Miller, TT ;
Math, K ;
Schultz, E .
SKELETAL RADIOLOGY, 2004, 33 (07) :380-385
[10]
Plenk H, 1997, CLIN ORTHOP RELAT R, P73