Sample preparation of Gram-positive bacteria for identification by matrix assisted laser desorption/ionization time-of-flight

被引:63
作者
Smole, SC
King, LA
Leopold, PE
Arbeit, RD
机构
[1] Boston Univ, Sch Med, Dept Med, Boston, MA 02118 USA
[2] Boston Vet Affairs Med Ctr, Res Serv, Boston, MA USA
[3] ProteiGene Inc, Billerica, MA USA
[4] Boston Univ, Sch Med, Dept Microbiol, Boston, MA 02118 USA
关键词
bacterial identifications; MALDI ToF MS; mass spectrometry; sample preparation;
D O I
10.1016/S0167-7012(01)00315-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new sample preparation method was developed for fresh, whole-cell Gram-positive bacteria to be analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI ToF MS). With fresh, whole-cell Gram-negative bacteria of the Enterobacteriaceae family, we had previously achieved spectra consisting of > 50 peaks and mass ranges of 225 kDa. Because similar spectral quantity could not be achieved for Gram-positive bacteria, using this same protocol, we investigated an alternative approach that focuses on the thick peptidoglycan layer of the cell wall. Gram-positive bacteria were incubated with 0.05-0.5 mg/ml lysozyme for 30 min prior to being analyzed by MALDI ToF MS. Lysozyme is an enzymatically stable, 14-kDa protein that specifically cleaves between peptidoglycan disaccharide subunits. A significant increase in overall number of peaks (>50) in the 2-14 kDa range was observed without interference from the presence of lysozyme. We show that for four different species (Staphylococcus aureus, S. haemolyticus, Streptococcus pyogenes, and S. agalactiae) reproducible subset of peaks were found within spectra from a reference strain and two unrelated clinical isolates. The data suggests that this sample preparation may be useful for increasing the overall number of peaks within spectra for subsequent development of bacterial identification strategies. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:107 / 115
页数:9
相关论文
共 16 条
[1]  
Arnold RJ, 1998, RAPID COMMUN MASS SP, V12, P630, DOI 10.1002/(SICI)1097-0231(19980529)12:10<630::AID-RCM206>3.3.CO
[2]  
2-S
[3]   PULSED-FIELD GEL-ELECTROPHORESIS AS A REPLACEMENT FOR BACTERIOPHAGE-TYPING OF STAPHYLOCOCCUS-AUREUS [J].
BANNERMAN, TL ;
HANCOCK, GA ;
TENOVER, FC ;
MILLER, JM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (03) :551-555
[4]   The rapid identification of intact microorganisms using mass spectrometry [J].
Claydon, MA ;
Davey, SN ;
EdwardsJones, V ;
Gordon, DB .
NATURE BIOTECHNOLOGY, 1996, 14 (11) :1584-1586
[5]  
Conway GC, 2001, J MOL MICROB BIOTECH, V3, P103
[6]   Microorganism identification by mass spectrometry and protein database searches [J].
Demirev, PA ;
Ho, YP ;
Ryzhov, V ;
Fenselau, C .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2732-2738
[7]   Rapid discrimination between methicillin-sensitive and methicillin-resistant Staphylococcus aureus by intact cell mass spectrometry [J].
Edwards-Jones, V ;
Claydon, MA ;
Evason, DJ ;
Walker, J ;
Fox, AJ ;
Gordon, DB .
JOURNAL OF MEDICAL MICROBIOLOGY, 2000, 49 (03) :295-300
[8]  
Fenselau C, 1994, MASS SPECTROMETRY CH
[9]  
Krishnamurthy T, 1996, RAPID COMMUN MASS SP, V10, P1992, DOI 10.1002/(SICI)1097-0231(199612)10:15<1992::AID-RCM789>3.0.CO
[10]  
2-V