Simultaneous determination of residual tetracyclines in foods by high-performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry

被引:106
作者
Nakazawa, H
Ino, S
Kato, K
Watanabe, T
Ito, Y
Oka, H
机构
[1] Hoshi Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Shinagawa Ku, Tokyo 1428501, Japan
[2] Aichi Prefectural Inst Publ Hlth, Kita Ku, Nagoya, Aichi 4628576, Japan
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 1999年 / 732卷 / 01期
关键词
tetracyclines;
D O I
10.1016/S0378-4347(99)00260-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We established a method for precisely determining residual tetracycline antibiotics (TCs) in foods by atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry (APCI LC-MS-MS) using selected reaction monitoring with an internal standard. By setting the nebulizer probe temperature to 475 degrees C, we were able to use a mobile phase containing oxalic acid without clogging problems at the APCI interface, since oxalic acid decomposes to carbon dioxide and water at high temperature. DMCTC was very effective as an internal standard for determining TCs in various foods. TCs were cleaned up using a Bond Elut ENV cartridge and analysed by APCI LC-MS-MS. The recovery of TCs from various foods including animal tissues, honey, milk, eggs, and fish fortified at levels of 0.05, 0.10, and 0.50 ppm averaged 60.1-88.9%, with an RSD of 1.2-8.7%. The detection limits were 0.001 ppm for OTC and TC, 0.004 ppm for CTC, and 0.002 ppm for DC, The present method was also successfully used to determine TCs in swine kidney samples that were previously found by microbiological assay. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 11 条
  • [1] Blanchflower WJ, 1997, J CHROMATOGR B, V692, P351
  • [2] HARADA KI, 1994, BIOL MASS SPECTROM, P606
  • [3] Quantitative determination of ceftiofur in milk by liquid chromatography electrospray mass spectrometry
    Keever, J
    Voyksner, RD
    Tyczkowska, KL
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) : 57 - 62
  • [4] KENION GB, 1990, ACS SYM SER, V420, P140
  • [5] CONFIRMATION OF OXYTETRACYCLINE, TETRACYCLINE AND CHLORTETRACYCLINE RESIDUES IN MILK BY PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    KIJAK, PJ
    LEADBETTER, MG
    THOMAS, MH
    THOMPSON, EA
    [J]. BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (12) : 789 - 795
  • [6] IMPROVEMENT OF CHEMICAL-ANALYSIS OF ANTIBIOTICS .8. APPLICATION OF PREPACKED C-18 CARTRIDGE FOR THE ANALYSIS OF TETRACYCLINE RESIDUES IN ANIMAL LIVER
    OKA, H
    MATSUMOTO, H
    UNO, K
    HARADA, KI
    KADOWAKI, S
    SUZUKI, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 325 (01): : 265 - 274
  • [7] OKA H, 1991, J ASSOC OFF ANA CHEM, V74, P894
  • [8] Improvement of chemical analysis of antibiotics .23. Identification of residual tetracyclines in bovine tissues by electrospray high-performance liquid chromatography tandem mass spectrometry
    Oka, H
    Ikai, Y
    Ito, Y
    Hayakawa, J
    Harada, K
    Suzuki, M
    Odani, H
    Maeda, K
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 693 (02): : 337 - 344
  • [9] Oka H, 1995, J FOOD HYG SOC JPN, V36, P759, DOI 10.3358/shokueishi.36.759
  • [10] DETERMINATION OF BETA-LACTAM RESIDUES IN MILK USING PERFUSIVE-PARTICLE LIQUID-CHROMATOGRAPHY COMBINED WITH ULTRASONIC NEBULIZATION ELECTROSPRAY MASS-SPECTROMETRY
    STRAUB, R
    LINDER, M
    VOYKSNER, RD
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (21) : 3651 - 3658