Three-dimensional volume rendering of spiral CT data: Theory and method

被引:383
作者
Calhoun, PS
Kuszyk, BS
Heath, DG
Carley, JC
Fishman, EK
机构
[1] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] HipGraphics, Baltimore, MD USA
关键词
computed tomography (CT); image processing; technology; three-dimensional; volume rendering;
D O I
10.1148/radiographics.19.3.g99ma14745
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional (3D) medical images of computed tomographic (CT) data sets can be generated with a variety of computer algorithms. The three most commonly used techniques are shaded surface display, maximum intensity projection, and, more recently, 3D volume rendering. Implementation of 3D volume rendering involves volume data management, which relates to operations including acquisition, resampling, and editing of the data set; rendering parameters including window width and level, opacity, brightness, and percentage classification, and image display, which comprises techniques such as "fly-through" and "fly-around," multiple-view display, obscured structure and shading depth cues, and kinetic and stereo depth cues. An understanding of both the theory and method of 3D volume rendering is essential for accurate evaluation of the resulting images. Three-dimensional volume rendering is useful in a wide variety of applications but is just now being incorporated into commercially available software packages for medical imaging. Although further research is needed to determine the efficacy of 3D volume rendering in clinical applications, with wider availability and improved cost-to-performance ratios in computing, 3D volume rendering is likely to enjoy widespread acceptance in the medical community.
引用
收藏
页码:745 / 764
页数:20
相关论文
共 41 条
  • [1] Cabral B., 1994, P 1994 S VOLUME VISU, P91, DOI DOI 10.1145/197938.197972
  • [2] CAROTID-ARTERY STENOSIS - A PROSPECTIVE COMPARISON OF CT ANGIOGRAPHY AND CONVENTIONAL ANGIOGRAPHY
    CUMMING, MJ
    MORROW, IM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) : 517 - 523
  • [3] Volume rendering
    Drebin, Robert A.
    Carpenter, Loren
    Hanrahan, Pat
    [J]. Computer Graphics (ACM), 1988, 22 (04): : 65 - 74
  • [4] FIDELITY OF 3-DIMENSIONAL CT IMAGING FOR DETECTING FRACTURE GAPS
    DREBIN, RA
    MAGID, D
    ROBERTSON, DD
    FISHMAN, EK
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (03) : 487 - 489
  • [5] Evaluating the potential and problems of three-dimensional computed tomography measurements of arterial stenosis
    Ebert, DS
    Heath, DG
    Kuszyk, BS
    Edwards, L
    Shaw, CD
    Kukla, J
    Bedwell, T
    Fishman, EK
    [J]. JOURNAL OF DIGITAL IMAGING, 1998, 11 (03) : 151 - 157
  • [6] Fishman E K, 1986, Radiographics, V6, P7
  • [7] 3-DIMENSIONAL IMAGING AND DISPLAY OF MUSCULOSKELETAL ANATOMY
    FISHMAN, EK
    MAGID, D
    NEY, DR
    DREBIN, RA
    KUHLMAN, JE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) : 465 - 467
  • [8] ADVANCED 3-DIMENSIONAL EVALUATION OF ACETABULAR TRAUMA - VOLUMETRIC IMAGE-PROCESSING
    FISHMAN, EK
    MAGID, D
    DREBIN, RA
    BROOKER, AF
    SCOTT, WJ
    RILEY, LH
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1989, 29 (02) : 214 - 218
  • [9] Automated bone editing algorithm for CT angiography: Preliminary results
    Fishman, EK
    Liang, CC
    Kuszyk, BS
    Davi, SE
    Heath, DG
    Hentschel, D
    Duffy, SV
    Gupta, A
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) : 669 - 672
  • [10] VOLUMETRIC RENDERING TECHNIQUES - APPLICATIONS FOR 3-DIMENSIONAL IMAGING OF THE HIP
    FISHMAN, EK
    DREBIN, B
    MAGID, D
    SCOTT, WW
    NEY, DR
    BROOKER, AF
    RILEY, LH
    STVILLE, JA
    ZERHOUNI, EA
    SIEGELMAN, SS
    [J]. RADIOLOGY, 1987, 163 (03) : 737 - 738