Performance evaluation of a computer-aided detection algorithm for solid pulmonary nodules in low-dose and standard-dose MDCT chest examinations and its influence on radiologists

被引:33
作者
Das, M. [1 ]
Muehlenbruch, G. [1 ]
Heinen, S. [1 ]
Mahnken, A. H. [1 ]
Salganicoff, M. [2 ]
Stanzel, S. [3 ]
Guenther, R. W. [1 ]
Wildberger, J. E. [1 ]
机构
[1] RWTH Aachen Univ Hosp, Dept Diagnost Radiol, D-52074 Aachen, Germany
[2] CAD Applicat, Siemens Med Solut, Malvern, PA USA
[3] Rhein Westfal TH Aachen, Inst Med Stat, Aachen, Germany
关键词
D O I
10.1259/bjr/50635688
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate the performance of a computer-aided detection (CAD) algorithm in low-dose and full-dose multicletector-row CT (MDCT) of the thorax and its impact on radiologists' performance. Chest CT examinations of 77 patients were evaluated retrospectively for pulmonary nodules. All patients had undergone a 16-slice MDCT chest examination with a standard acquistion protocol. Artificial image noise was added to the raw data to simulate image acquisition at 10 mAS(eff). The data were transferred to dedicated lung analysis software (LungCare (TM)) with a prototype CAD algorithm (LungCAD (TM)). CAD was applied to both dose settings. images were read by a radiologist and a first-year resident with and without the software at both dose settings. All images were reviewed in consensus by the two radiologists to set the reference standard. Sensitivity results with respect to the reference standard were compared. No statistically significant differences in the detection rate for all pulmonary nodules could be found between low-dose and full-dose settings for the CAD software alone (p=0.0065). Both radiologists displayed a statistically significant increase in sensitivity with the use of CAD (p<0.0001). In conclusion, CAD is beneficial in both low-dose and standard-dose settings. This may be beneficial in reducing false-negative diagnosis in lung cancer screening, standard chest examinations and the search for metastases.
引用
收藏
页码:841 / 847
页数:7
相关论文
共 32 条
[1]   Computerized scheme for automated detection of lung nodules in low-dose computed tomography images for lung cancer screening [J].
Arimura, H ;
Katsuragawa, S ;
Suzuki, K ;
Li, F ;
Shiraishi, J ;
Sone, S ;
Doi, K .
ACADEMIC RADIOLOGY, 2004, 11 (06) :617-629
[2]   Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[3]   Lung micronodules: Automated method for detection at thin-section CT - Initial experience [J].
Brown, MS ;
Goldin, JG ;
Suh, RD ;
McNitt-Gray, MF ;
Sayre, JW ;
Aberle, DR .
RADIOLOGY, 2003, 226 (01) :256-262
[4]   Asbestos Surveillance Program Aachen (ASPA):: initial results from baseline screening for lung cancer in asbestos-exposed high-risk individuals using low-dose multidetector-row CT [J].
Das, Marco ;
Muehlenbruch, Georg ;
Mahnken, Andreas H. ;
Hering, K. G. ;
Sirbu, H. ;
Zschiesche, W. ;
Knoll, Lars ;
Felten, Michael K. ;
Kraus, Thomas ;
Guenther, Rolf W. ;
Wildberger, Joachim E. .
EUROPEAN RADIOLOGY, 2007, 17 (05) :1193-1199
[5]   Small pulmonary nodules:: Effect of two computer-aided detection systems on radiologist performance [J].
Das, Marco ;
Muehlenbruch, Georg ;
Mahnken, Andreas H. ;
Flohr, Thomas G. ;
Guendel, Lutz ;
Stanzel, Sven ;
Kraus, Thomas ;
Guenther, Rolf W. ;
Wildberger, Joachim E. .
RADIOLOGY, 2006, 241 (02) :564-571
[6]   Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers [J].
Diederich, S ;
Wormanns, D ;
Semik, M ;
Thomas, M ;
Lenzen, H ;
Roos, N ;
Heindel, W .
RADIOLOGY, 2002, 222 (03) :773-781
[7]   COMPUTERIZED DETECTION OF PULMONARY NODULES IN COMPUTED-TOMOGRAPHY IMAGES [J].
GIGER, ML ;
BAE, KT ;
MACMAHON, H .
INVESTIGATIVE RADIOLOGY, 1994, 29 (04) :459-465
[8]   Automated lung nodule detection at low-dose CT: Preliminary experience [J].
Goo, JM ;
Lee, JW ;
Lee, HJ ;
Kim, S ;
Kim, JH ;
Im, JG .
KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (04) :211-216
[9]   Missed lung cancer at CT: Imaging findings in nine patients [J].
Gurney, JW .
RADIOLOGY, 1996, 199 (01) :117-122
[10]   Lung cancer screening with low-dose computed tomography [J].
Hartman, TE ;
Swensen, SJ .
SEMINARS IN ROENTGENOLOGY, 2003, 38 (01) :34-38