Protein tryptic digests analyzed by carrier ampholyte-based capillary electrophoresis coupled to ESI-MS

被引:20
作者
Busnel, JM
Descroix, S
Le Saux, T
Terabe, S
Hennion, MC
Peltre, G
机构
[1] ESPCI, Lab Environm & Chim Analyt, UMR 7121, CNRS, F-75005 Paris, France
[2] Univ Hyogo, Grad Sch Mat Sci, Kamigori, Hyogo, Japan
关键词
carrier ampholytes; protein tryptic digest; carrier ampholyte-based electrophoresis; low conductivity; ESI-MS;
D O I
10.1002/elps.200500808
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, narrow pH cuts of carrier ampholytes have been used as buffers in CE for the analysis of protein tryptic digests. Their low conductivity allows very efficient separations under high electric field strength without inducing any significant Joule heating. In this study, the capabilities of narrow pH cuts of carrier ampholytes for the separation of protein tryptic digests have been assessed. Three proteins of different molecular masses have been studied: cytochrome C (horse heart), P-lactoglobulin B (bovine) and human transferrin. Efficient, rapid and repeatable separations of the peptides resulting from the tryptic digestion have been achieved in this buffer. Moreover, the feasibility of the coupling of carrier ampholyte-based capillary electrophoresis with ESI-MS has been demonstrated through the study of the cytochrome C tryptic digest.
引用
收藏
页码:1481 / 1488
页数:8
相关论文
共 32 条
[1]  
ANTONIOLI P, IN PRESS J CHROMAT B
[2]   Protein separation by electrophoresis in a nonsieving amphoteric medium [J].
Blanco, S ;
Clifton, MJ ;
Joly, JL ;
Peltre, G .
ELECTROPHORESIS, 1996, 17 (06) :1126-1133
[3]   Generation of peptide maps by capillary zone electrophoresis in isoelectric iminodiacetic acid [J].
Bossi, A ;
Righetti, PG .
ELECTROPHORESIS, 1997, 18 (11) :2012-2018
[4]   Separation of peptides in isoelectric cysteic acid buffer and hydro-organic solvents (hexafluoro-2-propanol-urea) [J].
Bossi, A ;
Righetti, PG .
JOURNAL OF CHROMATOGRAPHY A, 1999, 840 (01) :117-129
[5]   Loading capacity of carrier ampholytes based buffers in capillary electrophoresis [J].
Busnel, JM ;
Descroix, S ;
Godfrin, D ;
Hennion, MC ;
Peltre, G .
ELECTROPHORESIS, 2006, 27 (03) :563-571
[6]   Carrier ampholytes-based capillary electrophoresis as an alternative to capillary zone electrophoresis in classical background electrolytes [J].
Busnel, JM ;
Kilár, F ;
Kasicka, V ;
Descroix, S ;
Hennion, MC ;
Peltre, G .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1087 (1-2) :183-188
[7]   Carrier ampholytes as potential buffers in electrophoresis: physico-chemical study [J].
Busnel, JM ;
Hennion, MC ;
Peltre, G .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 818 (01) :99-107
[8]  
Gianazza E, 1999, ELECTROPHORESIS, V20, P1325, DOI 10.1002/(SICI)1522-2683(19990601)20:7<1325::AID-ELPS1325>3.3.CO
[9]  
2-O
[10]   FAST, HIGH-RESOLUTION (CAPILLARY) ELECTROPHORESIS IN BUFFERS DESIGNED FOR HIGH-FIELD STRENGTHS [J].
HJERTEN, S ;
VALTCHEVA, L ;
ELENBRING, K ;
LIAO, JL .
ELECTROPHORESIS, 1995, 16 (04) :584-594