Heparin after percutaneous intervention (HAPI): A prospective multicenter randomized trial of three heparin regimens after successful coronary intervention

被引:40
作者
Rabah, M
Mason, D
Muller, DWM
Hundley, R
Kugelmass, AD
Weiner, B
Cannon, L
O'Neill, WW
Safian, RD
机构
[1] William Beaumont Hosp, Div Cardiol, Royal Oak, MI 48073 USA
[2] St Vincents Hosp, Dept Cardiol, Sydney, NSW 2010, Australia
[3] Baptist Med Ctr, Dept Cardiol, Little Rock, AR USA
[4] Univ Oklahoma, Hlth Sci Ctr, Dept Cardiol, Oklahoma City, OK USA
[5] Univ Massachusetts, Med Ctr, Dept Cardiol, Worcester, MA USA
[6] Dept Cardiol, Saginaw, MI USA
关键词
D O I
10.1016/S0735-1097(99)00195-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to determine the incidence of bleeding, vascular, and ischemic complications using three different heparin regimens after successful intervention. BACKGROUND The ideal dose and duration of heparin infusion after successful coronary intervention is unknown. METHODS Patients were randomized to one of three heparin strategies after coronary intervention: Group 1 (n = 157 patients) received prolonged (12 to 24 h) heparin infusion followed by sheath removal; Group 2 (n = 120 patients) underwent early removal of sheaths, followed by reinstitution of heparin infusion for 12 to 18 h; Group 3 (n = 137 patients) did not receive any further heparin after intervention with early sheath removal. The primary end point of the study was the combined incidence of in-hospital bleeding and vascular events. Secondary end points included in-hospital ischemic events, length of stay, cost and one-month outcome. RESULTS After successful coronary intervention, 414 patients were randomized. Unstable angina or postinfarction angina was present in 83% of patients before intervention. The combined incidence of bleeding and vascular events was 21% in Group 1, 14% in Group 2 and 8% in Group 3 (p = 0.01). The overall incidence of in-hospital ischemic complications was 2.2%; there were no differences between groups. Length of hospital stay was shorter (p = 0.033) and adjusted hospital cost was lower (p < 0.001) for Group 3. At 30 days, the incidence of delayed cardiac and vascular events was similar for all three groups. CONCLUSIONS Heparin infusion after successful coronary intervention is associated with more minor bleeding and vascular injury, prolonged length of stay and increased cost. In-hospital and one-month ischemic events rarely occur after successful intervention, irrespective of heparin use. Routine postprocedure heparin is not recommended, even in patients who present with unstable ischemic syndromes. (C) 1999 by the American College of Cardiology.
引用
收藏
页码:461 / 467
页数:7
相关论文
共 48 条
[1]   BLEEDING COMPLICATIONS WITH THE CHIMERIC ANTIBODY TO PLATELET GLYCOPROTEIN IIB/IIIA INTEGRIN IN PATIENTS UNDERGOING PERCUTANEOUS CORONARY INTERVENTION [J].
AGUIRRE, FV ;
TOPOL, EJ ;
FERGUSON, JJ ;
ANDERSON, K ;
BLANKENSHIP, JC ;
HEUSER, RR ;
SIGMON, K ;
TAYLOR, M ;
GOTTLIEB, R ;
HANOVICH, G ;
ROSENBERG, M ;
DONOHUE, TJ ;
WEISMAN, HF ;
CALIFF, RM .
CIRCULATION, 1995, 91 (12) :2882-2890
[2]  
ALENDANO A, 1994, J AM COLL CARDIOL, V23, P907
[3]   Incidence and predictors of bleeding after contemporary thrombolytic therapy for myocardial infarction [J].
Berkowitz, SD ;
Granger, CB ;
Peiper, KS ;
Lee, KL ;
Gore, JM ;
Simoons, M ;
Armstrong, PW ;
Topol, EJ ;
Califf, RM .
CIRCULATION, 1997, 95 (11) :2508-2516
[4]   COMPARATIVE SAFETY PROFILES OF HIRULOG AND HEPARIN IN PATIENTS UNDERGOING CORONARY ANGIOPLASTY [J].
BITTL, JA .
AMERICAN HEART JOURNAL, 1995, 130 (03) :658-665
[5]   USE OF A MONOCLONAL-ANTIBODY DIRECTED AGAINST THE PLATELET GLYCOPROTEIN IIB/IIIA RECEPTOR IN HIGH-RISK CORONARY ANGIOPLASTY [J].
CALIFF, RM ;
SHADOFF, N ;
VALETT, N ;
BATES, E ;
GALEANA, A ;
KNOPF, W ;
SHAFTEL, J ;
BENDER, MJ ;
AVERSANO, T ;
RAQUENO, J ;
GURBEL, P ;
COWFER, J ;
COHEN, M ;
CROSS, P ;
BITTL, J ;
EDDINGS, K ;
TAYLOR, M ;
DEROSA, K ;
HATTEL, L ;
COOPER, L ;
ESHELMAN, B ;
FINTEL, D ;
NIEMYSKI, P ;
KLEIN, L ;
KENNEDY, H ;
THORNTON, T ;
KEREIAKES, D ;
MARTIN, L ;
ANDERSON, L ;
HIGBY, N ;
ELLIS, S ;
BREZINA, K ;
GEORGE, B ;
CHAPEKIS, A ;
SMITH, D ;
ANWAR, A ;
GERBER, TL ;
PRITCHARD, GL ;
MYLER, R ;
SHAW, R ;
MURPHY, M ;
WARD, K ;
MADIGAN, NP ;
BLANKENSHIP, J ;
HALBERT, M ;
FLANAGAN, C ;
TANNENBAUM, M ;
POLICH, M ;
STEVENSON, C ;
TCHENG, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 330 (14) :956-961
[6]   COLLAGEN APPLICATION VERSUS MANUAL COMPRESSION - A PROSPECTIVE RANDOMIZED TRIAL FOR ARTERIAL PUNCTURE SITE CLOSURE AFTER CORONARY ANGIOPLASTY [J].
CAMENZIND, E ;
GROSSHOLZ, M ;
URBAN, P ;
DORSAZ, PA ;
DIDIER, D ;
MEIER, B .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (03) :655-662
[7]   ACUTE CORONARY-ARTERY OCCLUSION DURING AND AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - FREQUENCY, PREDICTION, CLINICAL COURSE, MANAGEMENT, AND FOLLOW-UP [J].
DEFEYTER, PJ ;
VANDENBRAND, M ;
JAARMAN, G ;
VANDOMBURG, R ;
SERRUYS, PW ;
SURYAPRANATA, H .
CIRCULATION, 1991, 83 (03) :927-936
[8]   PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY IN 1985-1986 AND 1977-1981 - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE REGISTRY [J].
DETRE, K ;
HOLUBKOV, R ;
KELSEY, S ;
COWLEY, M ;
KENT, K ;
WILLIAMS, D ;
MYLER, R ;
FAXON, D ;
HOLMES, D ;
BOURASSA, M ;
BLOCK, P ;
GOSSELIN, A ;
BENTIVOGLIO, L ;
LEATHERMAN, L ;
DORROS, G ;
KING, S ;
GALICHIA, J ;
ALBASSAM, M ;
LEON, M ;
ROBERTSON, T ;
PASSAMANI, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (05) :265-270
[9]   PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - REPORT OF COMPLICATIONS FROM THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE PTCA REGISTRY [J].
DORROS, G ;
COWLEY, MJ ;
SIMPSON, J ;
BENTIVOGLIO, LG ;
BLOCK, PC ;
BOURASSA, M ;
DETRE, K ;
GOSSELIN, AJ ;
GRUNTZIG, AR ;
KELSEY, SF ;
KENT, KM ;
MOCK, MB ;
MULLIN, SM ;
MYLER, RK ;
PASSAMANI, ER ;
STERTZER, SH ;
WILLIAMS, DO .
CIRCULATION, 1983, 67 (04) :723-730
[10]   ACTIVATED CLOTTING TIMES AND ACTIVATED PARTIAL THROMBOPLASTIN TIMES IN PATIENTS UNDERGOING CORONARY ANGIOPLASTY WHO RECEIVE BOLUS DOSES OF HEPARIN [J].
DOUGHERTY, KG ;
GAOS, CM ;
BUSH, HS ;
LEACHMAN, DR ;
FERGUSON, JJ .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 26 (04) :260-263