A novel constrained acetabular liner design with increased range of motion

被引:28
作者
Burroughs, BR [1 ]
Golladay, GJ [1 ]
Hallstrom, B [1 ]
Harris, WH [1 ]
机构
[1] Massachusetts Gen Hosp, Orthopaed Biomech & Biomat Lab, Boston, MA 02114 USA
关键词
constrained acetabular component; total hip dislocation;
D O I
10.1054/arth.2001.28361
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One treatment strategy for recurrent dislocation after total hip arthroplasty is the use of a constrained acetabular component. A major drawback of currently available constrained components is the limited range of motion (ROM). We present a novel constrained component that employs a monopolar, highly cross-linked polyethylene liner with cutouts oriented to allow increased ROM, while maintaining constraint against dislocation. ROM and lever-out tests comparing this novel design with a conventional constrained component showed that the cutaway monopolar component allowed ROM substantially greater than a currently available design. The lever-out torque for the cutaway monopolar constrained component was 243% higher than the conventional constrained component. This novel constrained acetabular component offers promise for providing excellent constraint against dislocation, while maintaining a wide ROM.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 24 条
[1]  
Anderson M J, 1994, J Arthroplasty, V9, P17, DOI 10.1016/0883-5403(94)90133-3
[2]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[3]   In vivo determination of hip joint separation and the forces generated due to impact loading conditions [J].
Dennis, DA ;
Komistek, RD ;
Northcut, EJ ;
Ochoa, JA ;
Ritchie, A .
JOURNAL OF BIOMECHANICS, 2001, 34 (05) :623-629
[4]  
ETIENNE A, 1978, CLIN ORTHOP RELAT R, P19
[5]  
Fisher D A, 1994, J Arthroplasty, V9, P325, DOI 10.1016/0883-5403(94)90088-4
[6]   REVISION OF THE CHARNLEY LOW-FRICTION ARTHROPLASTY FOR RECURRENT OR IRREDUCIBLE DISLOCATION [J].
FRASER, GA ;
WROBLEWSKI, BM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1981, 63 (04) :552-555
[7]  
Goetz DD, 1998, CLIN ORTHOP RELAT R, P171
[8]  
GRIGORIS P, 1994, CLIN ORTHOP RELAT R, P148
[9]  
Harman M, 2001, 47 ANN M ORTH RES SO
[10]   INVIVO WEAR OF POLYETHYLENE ACETABULAR COMPONENTS [J].
KABO, JM ;
GEBHARD, JS ;
LOREN, G ;
AMSTUTZ, HC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :254-258