Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach

被引:162
作者
Teng, XF [1 ]
Zhang, YT [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Joint Res Ctr Biomed Engn, Hong Kong, Hong Kong, Peoples R China
来源
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH | 2003年 / 25卷
关键词
blood pressure; photoplethysmography; noninvasive measurement;
D O I
10.1109/IEMBS.2003.1280811
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arterial blood pressure is one of the most important physiological parameters for the noninvasive diagnosis and monitoring of cardiovascular diseases. This study examines the relationships between arterial blood pressure and certain features of the photoplethysmographic (PPG) signals obtained from 15 young healthy subjects. Width of 1/2 pulse amplitude, width of 2/3 pulse amplitude, systolic upstroke time and diastolic time of the pulse were selected as features of the PPG signals. The experiment involved three sessions: rest, step-climbing exercise, and recovery from exercise. It was found that the diastolic time has higher correlation with systolic blood pressure (SBP) and diastolic blood pressure (DBP) than other features. The mean differences between the estimated and the measured blood pressure using a standard device are 0.21 mmHg for SBP and 0.02 mmHg for DBP. The corresponding standard deviations are 7.32 mmHg for SBP and 4.39 mmHg for DBP. The preliminary results indicate that it is possible to use the photoplethysmography only for cuffless and continuous estimation of arterial blood pressure.
引用
收藏
页码:3153 / 3156
页数:4
相关论文
共 11 条
[1]  
AWAD AA, 2001, BLOOD PRESSURE DETER
[2]   CAN PULSE OXIMETRY BE USED TO MEASURE SYSTOLIC BLOOD-PRESSURE [J].
CHAWLA, R ;
KUMARVEL, V ;
GIRDHAR, KK ;
SETHI, AK ;
INDRAYAN, A ;
BHATTACHARYA, A .
ANESTHESIA AND ANALGESIA, 1992, 74 (02) :196-200
[3]   PULSE TRANSIT-TIME AS AN INDICATOR OF ARTERIAL BLOOD-PRESSURE [J].
GEDDES, LA ;
VOELZ, MH ;
BABBS, CF ;
BOURLAND, JD ;
TACKER, WA .
PSYCHOPHYSIOLOGY, 1981, 18 (01) :71-74
[4]  
Kerola J, 1997, P IEEE EMBS, V18, P1308, DOI 10.1109/IEMBS.1996.652825
[5]  
Khalili Gholam Reza, 2002, Acta Anaesthesiol Sin, V40, P3
[6]  
MARINO FJ, 1984, PHARM DOSAGE FORMS P, V2, P1
[7]  
Meigas K, 2001, P ANN INT IEEE EMBS, V23, P3171, DOI 10.1109/IEMBS.2001.1019495
[8]   AORTIC-RADIAL PULSE TRANSIT-TIME AND ECG Q-WAVE TO RADIAL PULSE-WAVE INTERVAL AS INDEXES OF BEAT-BY-BEAT BLOOD-PRESSURE CHANGE [J].
POLLAK, MH ;
OBRIST, PA .
PSYCHOPHYSIOLOGY, 1983, 20 (01) :21-28
[9]  
ROBERT AA, 1981, PSYCHOPHYSIOLOGY, V18, P301, DOI DOI 10.1111/J.1469-8986.1981.TB03038.X
[10]   MEASUREMENT OF SYSTOLIC BLOOD-PRESSURE USING PULSE OXIMETRY DURING HELICOPTER FLIGHT [J].
TALKE, PO .
CRITICAL CARE MEDICINE, 1991, 19 (07) :934-937