An Evaluation of Biocompatibility of Indigenously Produced Pure Titanium: An Experimental Study in Rabbits

被引:2
作者
Chittaranjan, Bhogisetty [1 ]
Murthy, Bhamidipati Sreerama [2 ]
Ravindranath, Turaga [3 ]
机构
[1] ITS CDSR, Dept Prosthodont, Muradnagar, India
[2] Govt Dent Coll, Hyderabad, Andhra Pradesh, India
[3] Army Dent Coll, Secunderabad, India
关键词
indigenously produced pure titanium; biocompatibility; osseointegration;
D O I
10.1563/AAID-JOI-D-09-00099
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
The indigenously produced pure titanium dental implants are economical and useful for common human use in India. The aim of this study is to test the biocompatibility of the indigenously produced pure titanium dental implant material obtained from the Defense Metallurgical Research Laboratory, Hyderabad, India, and the Institute of Nuclear Medicine and Allied Science, Delhi, India. An experimental study in rabbits was done to study the amount of ordered bone formation around the screw and cylinder type of indigenously produced pure titanium metal implant specimens. The experimental animals were killed at 4, 6, 8, 12, and 16 weeks from the date of implantation. The histopathological examination of the animals killed at 16 weeks demonstrates the presence of osteoblastic cell proliferation and early ordered bone formation toward the implant site, indicating signs of osseointegration of both screw- and cylinder-type indigenously produced pure titanium specimens.
引用
收藏
页码:575 / 580
页数:6
相关论文
共 23 条
[1]
MECHANICAL-PROPERTIES AND BIOMECHANICAL COMPATIBILITY OF POROUS TITANIUM FOR DENTAL IMPLANTS [J].
ASAOKA, K ;
KUWAYAMA, N ;
OKUNO, O ;
MIURA, I .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (06) :699-713
[2]
BRANEMARK PI, 1983, TISSUE INTEGRATED PR
[3]
Branemark PI, 1985, OSSEOINTEGRATION CLI, P108
[4]
TEMPERATURE THRESHOLD LEVELS FOR HEAT-INDUCED BONE TISSUE-INJURY - A VITAL-MICROSCOPIC STUDY IN THE RABBIT [J].
ERIKSSON, AR ;
ALBREKTSSON, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (01) :101-107
[5]
THE BIOCOMPATIBILITY OF DENTAL IMPLANT MATERIALS MEASURED IN AN ANIMAL-MODEL [J].
GARCIA, DA ;
SULLIVAN, TM ;
ONEILL, DM .
JOURNAL OF DENTAL RESEARCH, 1981, 60 (01) :44-49
[6]
Histological and histomorphometrical evaluation of tissue reactions adjacent to endosteal implants in monkey's [J].
Gotfredsen, Klaus ;
Rostrup, Egill ;
Hjorting-Hansen, Erik ;
Stoltze, Kaj ;
Budtz-Joergensen, Ejvind .
CLINICAL ORAL IMPLANTS RESEARCH, 1991, 2 (01) :30-37
[7]
Hobo S., 1990, THEORY PRACTICE OSSE
[8]
Johansson C, 1987, Int J Oral Maxillofac Implants, V2, P69
[9]
LEMONS J, 1986, DENT CLIN N AM, V30, P3
[10]
Leonard LI., 1970, THEORIES TECHNIQUES, V1