PMMA-augmented SI screw: a biomechanical analysis of stiffness and pull-out force in a matched paired human cadaveric model

被引:42
作者
Grechenig, Stephan [1 ]
Gaensslen, Axel [2 ]
Gueorguiev, Boyko [3 ]
Berner, Arne [1 ]
Mueller, Michael [1 ]
Nerlich, Michael [1 ]
Schmitz, Paul [1 ]
机构
[1] Univ Regensburg, Clin Trauma Surg, D-93053 Regensburg, Germany
[2] Clin Wolfsburg, Dept Trauma Surg, Wolfsburg, Germany
[3] AO Res Inst Davos, Davos, Switzerland
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷
关键词
SI-screw; pelvic ring fracture; augmentation; biomechanics; SACRAL INSUFFICIENCY FRACTURES; ILIOSACRAL SCREW; RING FRACTURES; FIXATION; CEMENT; PELVIS; POLYMETHYLMETHACRYLATE; SACROPLASTY; MULTICENTER; PLACEMENT;
D O I
10.1016/S0020-1383(15)30031-0
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Introduction: Current literature data and clinical experience show that the number of pelvic fractures continuously rises due to the increasing elderly population. In the elderly with suspected osteoporosis additional implant augmentation with bone cement seems to be an option to avoid secondary displacement. There are no reported biomechanical data in the literature comparing the fixation strength (and anchorage) of standard and augmented SI screws so far. The purpose of this study was to assess the biomechanical performance of cement-augmented versus non-augmented SI screws in a human cadaveric pelvis model. Material and Methods: Six human cadaveric pelvises preserved with the method of Thiel were used in this study. Each pelvis was split to a pair of 2 hemi-pelvises, assigned to 2 different groups for instrumentation with one non-augmented or one contralateral cement-augmented SI screw, placed in the body of S1 in a randomized fashion. The osteosynthesis followed a standard procedure with 3D controlled percutaneous iliosacral screw positioning. A biomechanical setup for a quasistatic pullout test of each SI screw was used. Construct stiffness and maximum pullout force were calculated from the load-displacement curve of the machine data. Statistical evaluation was performed at a level of significance p = .05 for all statistical tests. Results: Stiffness and pullout force in the augmented group (501.6 N/mm +/- 123.7, 1336.8 N +/- 221.1) were significantly higher than in the non-augmented one (289.7 N/mm +/- 97.1, 597.7 N +/- 115.5), p = .04 and p = .014, respectively. BMD influenced significantly the pullout force in all study groups. Conclusion: Cement augmentation significantly increased the fixation strength in iliosacral screw osteosynthesis of the sacrum in a biomechanical human cadaveric model. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S125 / S128
页数:4
相关论文
共 29 条
[1]
CHARNLEY J, 1970, Journal of Bone and Joint Surgery British Volume, V52, P340
[2]
Daum WJ, 1998, J ORTHOP TRAUMA, V2, P229
[3]
Internal architecture of the sacrum in the elderly - An anatomic and radiographic study [J].
Ebraheim, N ;
Sabry, FF ;
Nadim, Y ;
Xu, RM ;
Yeasting, RA .
SPINE, 2000, 25 (03) :292-297
[4]
A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation [J].
Frankel, Bruce M. ;
D'Agostino, Sabino ;
Wang, Chiang .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (01) :47-53
[5]
Percutaneous sacroplasty for osteoporotic sacral insufficiency fractures: a prospective, multicenter, observational pilot study [J].
Frey, Michael E. ;
DePalma, Michael J. ;
Cifu, David X. ;
Bhagia, Sarjoo M. ;
Carne, William ;
Daitch, Jonathan S. .
SPINE JOURNAL, 2008, 8 (02) :367-373
[6]
Pelvic ring fractures in the elderly. Underestimated osteoporotic fracture [J].
Fuchs, T. ;
Rottbeck, U. ;
Hofbauer, V. ;
Raschke, M. ;
Stange, R. .
UNFALLCHIRURG, 2011, 114 (08) :663-670
[7]
Biomechanical principles for treatment of osteoporotic fractures of the pelvis [J].
Gansslen, A. .
UNFALLCHIRURG, 2010, 113 (04) :272-+
[8]
Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis [J].
Giraldez-Sanchez, Miguel A. ;
Lazaro-Gonzalvez, Angel ;
Martinez-Reina, Javier ;
Serrano-Toledano, David ;
Navarro-Robles, Alfredo ;
Cano-Luis, Pedro ;
Fragkakis, Evangelos M. ;
Giannoudis, Peter V. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (02) :327-332
[9]
SOME PHYSIOLOGICAL ASPECTS OF PROSTHESIS STABILIZATION WITH ACRYLIC POLYMER [J].
HOMSY, CA ;
TULLOS, HS ;
ANDERSON, MS ;
KING, JW ;
DIFERRAN.NM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1972, (83) :317-&
[10]
Percutaneous iliosacral screw fixation after osteoporotic posterior ring fractures of the pelvis reduces pain significantly in elderly patients [J].
Hopf, Johannes Christof ;
Krieglstein, Christian F. ;
Mueller, Lars P. ;
Koslowsky, Thomas C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (08) :1631-1636