Time-resolved contrast-enhanced 3D MR angiography

被引:697
作者
Korosec, FR
Frayne, R
Grist, TM
Mistretta, CA
机构
[1] UNIV WISCONSIN,DEPT RADIOL,MADISON,WI 53792
[2] UNIV WISCONSIN,DEPT MED PHYS,MADISON,WI 53792
关键词
MR angiography; time-resolved MR imaging; contrast-enhanced MR imaging; rapid 3D MR imaging;
D O I
10.1002/mrm.1910360304
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An MR angiographic technique, referred to as 3D TRICKS (3D time-resolved imaging of contrast kinetics) has been developed, This technique combines and extends to 3D imaging several previously published elements, These elements include an increased sampling rate for lower spatial frequencies, temporal interpolation of k-space views, and zero-filling in the slice-encoding dimension, When appropriately combined, these elements permit reconstruction of a series of 3D image sets having an effective temporal frame rate of one volume every 2-6 s. Acquiring a temporal series of images offers advantages over the current contrast-enhanced 3D MRA techniques in that it i) increases the likelihood that an arterial-only 3D image set will be obtained, ii) permits the passage of the contrast agent to be observed, and iii) allows temporal-processing techniques to be applied to yield additional information, or improve image quality.
引用
收藏
页码:345 / 351
页数:7
相关论文
共 31 条
  • [1] FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE
    DOUEK, PC
    REVEL, D
    CHAZEL, S
    FALISE, B
    VILLARD, J
    AMIEL, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 431 - 437
  • [2] BLOCK REGIONAL INTERPOLATION SCHEME FOR K-SPACE (BRISK) - A RAPID CARDIAC IMAGING TECHNIQUE
    DOYLE, M
    WALSH, EG
    BLACKWELL, GG
    POHOST, GM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) : 163 - 170
  • [3] REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY
    DU, YPP
    PARKER, DL
    DAVIS, WL
    CAO, G
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 733 - 741
  • [4] MR ANGIOGRAPHY
    EDELMAN, RR
    MATTLE, HP
    ATKINSON, DJ
    HOOGEWOUD, HM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (05) : 937 - 946
  • [5] FREDRICKSON JO, 1995, P SMR 3 ANN M, P197
  • [6] EIGENIMAGE FILTERING IN MR IMAGING - AN APPLICATION IN THE ABNORMAL CHEST WALL
    HAGGAR, AM
    WINDHAM, JP
    REIMANN, DA
    HEARSHEN, DO
    FROELICH, JW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 11 (01) : 85 - 97
  • [7] HOLLAND GA, 1995, P SMR 3 ANN M, P77
  • [8] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    [J]. RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [9] KERR A, 1995, P SMR 3 ANN M NIC, P99
  • [10] A DATA ADAPTIVE REPROJECTION TECHNIQUE FOR MR ANGIOGRAPHY
    KOROSEC, FR
    WEBER, DM
    MISTRETTA, CA
    TURSKI, PA
    BERNSTEIN, MA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (02) : 262 - 274