Normality and stationarity of EMG signals of elbow flexor muscles during ramp and step isometric contractions

被引:93
作者
Bilodeau, M
Cincera, M
Arsenault, AB
Gravel, D
机构
[1] POLITECN MILAN, FDN PRO JUVENTUTE, CTR BIOINGN, MILAN, ITALY
[2] UNIV MONTREAL, FAC MED, SCH REHABIL, MONTREAL, PQ H3C 3J7, CANADA
[3] MONTREAL REHABIL INST, RES CTR, MONTREAL, PQ, CANADA
基金
英国医学研究理事会;
关键词
electromyography (EMG); signal processing; stationarity; amplitude distribution; isometric (static) contractions;
D O I
10.1016/S1050-6411(96)00024-7
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this study was to test the stationarity and normality of electromyographic (EMG) signals obtained while exerting isometric contractions: (a) when a steady force level is maintained (step contractions); and (b) where the force level is increased linearly over time (ramp contractions). Ramp elbow flexions were performed from 0 to 100% of the maximum voluntary contraction (MVC) in a 5-s period. For the step contractions, four force levels (20, 40, 60 and 80% MVC) were maintained for a period of 3s each. EMG signals of the biceps brachii (BE) and brachioradialis (BR) muscles of 16 subjects were recorded with surface electrodes and digitized at a sampling frequency of 2000 Hz. Tests of normality (Shapiro-Wilk test) and stationarity (reverse arrangement test) were performed locally on short finite time records (512-ms windows). Results show that, in general, EMC signals present a non-Gaussian amplitude distribution and are stationary. Furthermore, the amplitude distribution characteristics and the stationarity of the signal were not dependent on the muscle investigated, nor on the type of contraction or force level tested. The finding of local stationarity for both tasks is important, because it suggests that performing standard spectral analysis is applicable for both step and ramp contractions. It also allows a direct comparison between results obtained under both conditions. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:87 / 96
页数:10
相关论文
共 37 条
[1]  
Basmajian J. V., 1975, COMPUTERS ELECTROMYO
[2]  
Bendat J., 2010, Random data: analysis and measurement procedures
[3]   EMG POWER SPECTRA OF ELBOW EXTENSORS DURING RAMP AND STEP ISOMETRIC CONTRACTIONS [J].
BILODEAU, M ;
ARSENAULT, AB ;
GRAVEL, D ;
BOURBONNAIS, D .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1991, 63 (01) :24-28
[4]   THE INFLUENCE OF AN INCREASE IN THE LEVEL OF FORCE ON THE EMG POWER SPECTRUM OF ELBOW EXTENSORS [J].
BILODEAU, M ;
ARSENAULT, AB ;
GRAVEL, D ;
BOURBONNAIS, D .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1990, 61 (5-6) :461-466
[5]   TIME AND FREQUENCY-ANALYSIS OF EMG SIGNALS OF HOMOLOGOUS ELBOW FLEXORS AND EXTENSORS [J].
BILODEAU, M ;
ARSENAULT, AB ;
GRAVEL, D ;
BOURBONNAIS, D .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (06) :640-644
[6]   INFLUENCE OF GENDER ON THE EMG POWER SPECTRUM DURING AN INCREASING FORCE LEVEL [J].
BILODEAU, M ;
ARSENAULT, AB ;
GRAVEL, D ;
BOURBONNAIS, D .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1992, 2 (03) :121-129
[7]  
BILODEAU M, 1992, J BIOMECH, V26, P309
[8]  
Blackman R. B., 1958, MEASUREMENT POWER SP
[9]   BIO-MEDICAL SIGNAL-PROCESSING (IN 4 PARTS) .1. TIME-DOMAIN METHODS [J].
CHALLIS, RE ;
KITNEY, RI .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (06) :509-524
[10]   PHYSIOLOGY AND MATHEMATICS OF MYOELECTRIC SIGNALS [J].
DE LUCA, CJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (06) :313-325