Roll-over shapes of human locomotor systems: effects of walking speed

被引:143
作者
Hansen, AH [1 ]
Childress, DS
Knox, EH
机构
[1] Northwestern Univ, Feinberg Med Sch, Dept Phys Med & Rehabil, Chicago, IL 60611 USA
[2] Northwestern Univ, Robert R McCormick Sch Engn & Appl Sci, Evanston, IL 60208 USA
[3] Dept Vet Affairs, Lakeside Div, Chicago, IL USA
[4] Engn Syst Inc, Aurora, IL USA
关键词
foot; ankle; knee; rocker; cam; center of pressure; orthotics; prosthetics;
D O I
10.1016/j.clinbiomech.2003.12.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To examine the hypothesis that roll-over shapes of non-disabled lower limb systems do not change appreciably with walking speed. Design. Repeated measures (n = 24). Background. Roll-over shapes of three lower limb systems are presented. They are: roll-over shapes of the (1) foot, (2) ankle-foot, and (3) knee-ankle-foot systems. Roll-over shapes show the effective rocker (or cam) shapes that the lower limb systems conform to during the period in the stance phase of walking between heel contact and opposite heel contact. Methods. Roll-over shapes were measured by transforming center of pressure data from a laboratory-based coordinate system into each of three body-based coordinate systems. Knee-ankle-foot roll-over shapes were further characterized using a circular arc model. Results. From a statistical standpoint, the radii of the best-fit circular arcs did not change significantly with walking speed, while the forward shifts of the circular models did change significantly. However, the change in forward shift was not considered to be clinically significant. Conclusions. The biologic systems involved in developing the roll-over shapes adapt to changing conditions of walking speed, including increased loading amplitudes as speed is increased, to maintain similar effective roll-over geometries.
引用
收藏
页码:407 / 414
页数:8
相关论文
共 26 条
[1]  
Field A.P., 2004, DISCOVERING STAT USI, V2nd
[2]  
Gard S.A., 2001, J. Prosthet. Orthot, V13, P64, DOI [10.1097/00008526-200109000-00009, DOI 10.1097/00008526-200109000-00009]
[3]   Prosthetic foot roll-over shapes with implications for alignment of trans-tibial prostheses [J].
Hansen, AH ;
Childress, DS ;
Knox, EH .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2000, 24 (03) :205-215
[4]  
HANSEN AH, 2002, THESIS NW U EVANSTON
[5]  
HISS JM, 1937, FUNCTIONAL FOOT DISO
[6]  
JU M, 1986, THESIS CASE W RESERV
[7]   SIMULATION OF THE DOUBLE LIMB SUPPORT PHASE OF HUMAN GAIT [J].
JU, MS ;
MANSOUR, JM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (03) :223-229
[8]   MEASUREMENT OF LOWER-EXTREMITY KINEMATICS DURING LEVEL WALKING [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (03) :383-392
[9]   THE SPRING IN THE ARCH OF THE HUMAN FOOT [J].
KER, RF ;
BENNETT, MB ;
BIBBY, SR ;
KESTER, RC ;
ALEXANDER, RM .
NATURE, 1987, 325 (6100) :147-149
[10]   ROLE OF PLANTAR FASCIA IN THE LOAD-BEARING CAPACITY OF THE HUMAN FOOT [J].
KIM, W ;
VOLOSHIN, AS .
JOURNAL OF BIOMECHANICS, 1995, 28 (09) :1025-1033