Chromatographic determination of metallic impurities in reversed-phase HPLC columns

被引:47
作者
Engelhardt, H [1 ]
Lobert, T [1 ]
机构
[1] Univ Saarland, Inst Instrumental & Environm Anal, D-66123 Saarbrucken, Germany
关键词
D O I
10.1021/ac981198x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new test procedure is proposed for the characterization of packed RP columns with respect to their metal content. It is based on the peak asymmetry of 2,2'-bipyridyl, which can be directly correlated to the metal content of the stationary phase. Since an unbuffered eluent (methanol/ water, 49:51 w/w) is used, the influence of the simultaneously present silanol groups on peak asymmetry is assessed via 4,4'-bipyridyl, which exhibits no chelating activity. A metal factor, MF, is introduced, which is the ratio of the peak asymmetries of 2,2'-bipyridyl and 4,4'-bipyridyl multiplied by 100. The superiority of this test compared to others is demonstrated via various commercially available columns. It is also demonstrated that columns continuously collect metal ions from the column components and the instrument hardware. Stainless steel nets and hits are the principal source of the metallic contamination, But even in totally metal-free LC systems, the stationary phase collects metal ions from the HPLC grade eluent components.
引用
收藏
页码:1885 / 1892
页数:8
相关论文
共 22 条
  • [1] Cotton F.A., 1988, Advanced Inorganic Chemistry
  • [2] CATALYTIC-OXIDATION OF TRIPHENYL PHOSPHITE WITH FERRIC ION-MODIFIED CHROMATOGRAPHIC SILICA
    DENG, ZQ
    ZHANG, JZJ
    ELLIS, AB
    LANGER, SH
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (05): : 1083 - 1103
  • [3] Engelhardt H, 1997, LC GC-MAG SEP SCI, V15, P856
  • [4] PROPERTIES AND DIVERSITY OF C18 BONDED PHASES
    ENGELHARDT, H
    DREYER, B
    SCHMIDT, H
    [J]. CHROMATOGRAPHIA, 1982, 16 : 11 - 17
  • [5] ENGELHARDT H, 1981, J CHROMATOGR, V219, P395
  • [6] INVESTIGATIONS INTO THE EPIMERIZATION OF TIPREDANE ETHYLSULPHOXIDE DIASTEREOISOMERS DURING CHROMATOGRAPHIC ANALYSIS ON REVERSED-PHASE SILICA .1. INVESTIGATIONS INTO THE REACTION-MECHANISM
    EUERBY, MR
    JOHNSON, CM
    RUSHIN, ID
    TENNEKOON, DASS
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (02) : 219 - 227
  • [7] Iler R.K., 1979, The Chemistry of Silica
  • [8] SUPPRESSION OF THE EFFECT OF METAL IMPURITIES IN ALKYLSILYLATED SILICA PACKING MATERIALS
    KIMATA, K
    TANAKA, N
    ARAKI, T
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 594 (1-2): : 87 - 96
  • [9] INFLUENCE OF METAL IMPURITIES IN SILICA-GEL ON PROTEIN-ANALYSIS IN REVERSED-PHASE HPLC
    KOYAMA, J
    NOMURA, J
    OHTSU, Y
    NAKATA, O
    TAKAHASHI, M
    [J]. CHEMISTRY LETTERS, 1990, (04) : 687 - 690
  • [10] POSSIBLE ROLE FOR STATIONARY PHASE METAL INTERACTIONS IN THE CHROMATOGRAPHY OF HYDROXYAMINES ON SILICA
    LAW, B
    CHAN, PF
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 552 (1-2): : 429 - 438