Abdominal aortic aneurysm sac shrinkage after endovascular aneurysm repair: Correlation with chronic sac pressure measurement

被引:64
作者
Ellozy, SH
Carroccio, A
Lookstein, RA
Jacobs, TS
Addis, MD
Teodorescu, VJ
Marin, ML
机构
[1] CUNY Mt Sinai Sch Med, Dept Surg, Div Vasc Surg, New York, NY 10029 USA
[2] CUNY Mt Sinai Sch Med, Dept Radiol, Div Intervent Radiol, New York, NY 10029 USA
关键词
D O I
10.1016/j.jvs.2005.09.039
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives. Abdominal aortic aneurysm (AAA) sac shrinkage after endovascular aneurysm repair (EVAR) is considered to be evidence of clinical success. Exclusion of the sac from systemic pressure is the likely cause of shrinkage. We report our continuing clinical experience with the use of a permanently implantable, ultrasound-activated remote pressure transducer to measure intrasac pressure and its correlation with changes in sac diameter over time. Methods. Over a 22-month period, 21 patients underwent EVAR of an infrarenal AAA with implantation of an ultrasound-activated remote pressure transducer fixed to the outside of the stent-graft and exposed to the excluded aortic sac. Intrasac pressures were measured directly with an intravascular catheter and by the remote sensor at the time of stent-graft deployment. Follow-up sac pressures were measured by remote sensor and compared with systemic arterial pressure at every follow-up visit. Mean follow-up was 11.4 +/- 5.0 months (range, 1 to 26 months). Twenty patients had follow-up of :6 months. Mean pressure index (MPI) was calculated as the ratio of mean sac pressure to mean systemic pressure. Results. Pressures could be obtained at all visits in 15 of the 21 patients. Fourteen of these 15 patients had follow-up of at least 6 months. Aneurysm sac shrinkage of >5 turn was seen in seven (50%) of these 14 patients. No aneurysm enlargement was observed in any patient. The MPI was significantly lower in patients with sac shrinkage at 6 months and at final follow-up. Conclusions: Endovascular aneurysm repair results in marked reduction of sac pressure in most patients. Patients with aneurysm shrinkage after EVAR have significantly lower MPI; however, the absence of sac shrinkage does not imply persistent pressurization of the sac. Further clinical follow-up will delineate the role of long-term sac pressure monitoring in surveillance after EVAR.
引用
收藏
页码:2 / 6
页数:5
相关论文
共 21 条
[1]   A statewide experience with endovascular abdominal aortic aneurysm repair: Rapid diffusion with excellent early results - Discussion [J].
Matsumura, JS ;
Anderson, PL ;
Muluk, SC ;
Green, RM ;
Dardik, A ;
Ricotta, JJ .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (01) :18-19
[2]   Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms [J].
Baum, RA ;
Carpenter, RP ;
Cope, C ;
Golden, MA ;
Velazquez, OC ;
Neschis, DG ;
Mitchell, ME ;
Barker, CF ;
Fairman, RM .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (01) :32-40
[3]  
Chong CK, 2003, J ENDOVASC THER, V10, P424, DOI 10.1583/1545-1550(2003)010<0424:MEACRF>2.0.CO
[4]  
2
[5]   Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks [J].
Dias, NV ;
Ivancev, K ;
Malina, M ;
Resch, T ;
Lindblad, B ;
Sonesson, B .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (06) :1229-1235
[6]   First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms [J].
Ellozy, SH ;
Carroccio, A ;
Lookstein, RA ;
Minor, ME ;
Sheahan, CM ;
Juta, J ;
Cha, A ;
Valenzuela, R ;
Addis, MD ;
Jacobs, MS ;
Teodorescu, VJ ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2004, 40 (03) :405-411
[7]  
Faries PL, 1997, J ENDOVASC SURG, V4, P290, DOI 10.1583/1074-6218(1997)004<0290:AEMFTA>2.0.CO
[8]  
2
[9]   A multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysms [J].
Faries, PL ;
Brener, BJ ;
Connelly, TL ;
Katzen, BT ;
Briggs, VL ;
Burks, JA ;
Gravereaux, EC ;
Carroccio, A ;
Morrissey, NJ ;
Teodorescu, V ;
Won, J ;
Sparacino, S ;
Chae, KS ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (06) :1123-1128
[10]   Endovascular stent graft repair of abdominal and thoracic aortic aneurysms - A ten-year experience with 817 patients [J].
Marin, ML ;
Hollier, LH ;
Ellozy, SH ;
Spielvogel, D ;
Mitty, H ;
Griepp, R ;
Lookstein, RA ;
Carroccio, A ;
Morrissey, NJ ;
Teodorescu, VJ ;
Jacobs, TS ;
Minor, ME ;
Sheahan, CM ;
Chae, K ;
Oak, J ;
Cha, A .
ANNALS OF SURGERY, 2003, 238 (04) :586-593