Sodium citrate 4% versus heparin as a lock solution in hemodialysis patients with central venous catheters

被引:38
作者
Yon, Calantha K. [1 ,2 ]
Low, Chai L. [2 ,3 ]
机构
[1] Vet Affairs San Diego Healthcare Syst VASD, San Diego, CA USA
[2] Univ Calif San Diego, Skaggs Sch Pharm & Pharmaceut Sci, San Diego, CA 92103 USA
[3] VASD, Nephrol Pharm Residency Program, San Diego, CA USA
关键词
TRISODIUM CITRATE;
D O I
10.2146/ajhp120300
中图分类号
R9 [药学];
学科分类号
100702 [药剂学];
摘要
Purpose. The effects of heparin versus sodium citrate 4% as a lock solution on catheter-related infections (CRIs), catheter patency, and hospitalizations in long-term hemodialysis patients with central venous catheters (CVCs) were compared. Methods. Data for patients receiving heparin lock solutions were collected from July 2008 to July 2009. Data on patients receiving sodium citrate 4% lock solution were collected from September 2009 through December 2010. Patients who were receiving the heparin lock solution who continued to have a CVC in September 2009 were transitioned from heparin to sodium citrate catheter 4% lock solution. New patients with CVCs placed after September 2009 received sodium citrate 4% without a period of using heparin, lock solution. Pertinent information on patient medical history, bleeding or clotting events, infections, and hospitalization was collected. Data were collected retrospectively for the heparin group and prospectively for the sodium citrate group. Results. Data were collected from 360 patient-months among 60 patients during the heparin treatment period and from 451 patient-months among 58 patients during the sodium citrate period. Thirty-three patients were common to both study groups. There were significantly more CRIs and CRIs per 1000 catheter-days in the heparin than the sodium citrate treatment group. Secondary outcomes of hospitalizations and catheter thrombosis were comparable. CRIs and thrombosis led to significantly more catheter exchanges or removals in the heparin group than the sodium citrate group. Conclusion. In patients with long-term hemodialysis catheters, a lock solution of sodium citrate 4% was associated with fewer CRIs and similar effectiveness when compared with heparin 5000 units/mL. Am J Health-Syst Pharm. 2013; 70:131-6
引用
收藏
页码:131 / 136
页数:6
相关论文
共 13 条
[1]
Estimation of heparin leak into the systemic circulation after central venous catheter heparin lock [J].
Agharazii, M ;
Plamondon, I ;
Lebel, M ;
Douville, P ;
Desmeules, S .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 (06) :1238-1240
[3]
Ash Stephen R, 2000, Hemodial Int, V4, P22, DOI 10.1111/hdi.2000.4.1.22
[4]
*FDA, 2000, T0016 FDA
[5]
Sodium citrate 4% locking solution for central venous dialysis catheters - an effective, more cost-efficient alternative to heparin [J].
Grudzinski, Linda ;
Quinan, Patricia ;
Kwok, Sophie ;
Pierratos, Andreas .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (02) :471-476
[6]
Risk of heparin lock-related bleeding when using indwelling venous catheter in haemodialysis [J].
Karaaslan, H ;
Peyronnet, P ;
Benevent, D ;
Lagarde, C ;
Rince, M ;
Leroux-Robert, C .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (10) :2072-2074
[7]
Trisodium citrate 4% - an alternative to heparin capping of haemodialysis catheters [J].
Lok, Charmaine E. ;
Appleton, Debra ;
Bhola, Cynthia ;
Khoo, Brian ;
Richardson, Robert M. A. .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (02) :477-483
[8]
Sodium Citrate Versus Heparin Catheter Locks for Cuffed Central Venous Catheters: A Single-Center Randomized Controlled Trial [J].
Power, Albert ;
Duncan, Neill ;
Singh, Seema K. ;
Brown, Wendy ;
Dalby, Elizabeth ;
Edwards, Claire ;
Lynch, Kathleen ;
Prout, Virginia ;
Cairns, Tom ;
Griffith, Megan ;
McLean, Adam ;
Palmer, Andrew ;
Taube, David .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2009, 53 (06) :1034-1041
[9]
Vascular access results from the Dialysis Outcomes and Practice Patterns Study (DOPPS): Performance against Kidney Disease Outcomes Quality Initiative (K/DOQI) clinical practice guidelines [J].
Rayner, HC ;
Besarab, A ;
Brown, WW ;
Disney, A ;
Saito, A ;
Pisoni, RL .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2004, 44 (05) :S22-S26
[10]
Catheter lock solutions influence staphylococcal biofilm formation on abiotic surfaces [J].
Shanks, Robert M. Q. ;
Sargent, Jennifer L. ;
Martinez, Raquel M. ;
Graber, Martha L. ;
O'Toole, George A. .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (08) :2247-2255