Quantitative analysis of fuel-related hydrocarbons in surface water and wastewater samples by solid-phase microextraction

被引:196
作者
Langenfeld, JJ [1 ]
Hawthorne, SB [1 ]
Miller, DJ [1 ]
机构
[1] UNIV N DAKOTA,ENERGY & ENVIRONM RES CTR,GRAND FORKS,ND 58202
关键词
D O I
10.1021/ac950862w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-phase microextraction (SPME) parameters were examined on water contaminated with hydrocarbons including benzene and alkylbenzenes, n-alkanes, and polycyclic aromatic hydrocarbons (PAHs), Absorption equilibration times ranged from several minutes for low molecular weight compounds such as benzene to 5 h for high molecular weight compounds such as benzo[a]pyrene, Under equilibrium conditions, SPME analysis with GC/FID was linear over 3-6 orders of magnitude, with linear correlation coefficients (r(2)) greater than 0.96, Experimentally determined FID detection limits ranged from similar to 30 ppt (w/w hydrocarbon/sample water) for high molecular weight PAHs (e.g., MW > 202) to similar to 1 ppb for low molecular weight aromatic hydrocarbons, Experimental distribution constants (K) were different with 100- and 7-mu m poly(dimethylsiloxane) fibers, and poor correlations with previously published values suggest that K depends on the fiber coating thickness and the sorbent preparation method, The sensitivity of SPME analysis is not significantly enhanced by larger sample volumes, since increasing the water volume (e.g., from 1 to 100 mt) has little effect on the number of analyte molecules absorbed by the fiber, especially for compounds with K < 500, Water sample storage should utilize silanized glassware, since hydrocarbon losses up to 70% could be attributed to unsilanized glassware walls when samples were stored for 48 h, Hydrocarbon losses at part-per-billion concentrations also occurred with surface waters due to partitioning onto part-per-thousand concentrations of suspended solids, Quantitative determinations of aromatic and aliphatic hydrocarbons (e.g., in gasoline-contaminated water) can be performed using GC/MS with deuterated internal standard or standard addition calibration as long as the target components or standards had unique ions for quantitation or sufficient chromatographic resolution from interferences, SPME analysis gave good quantitative performance with surface waters having high suspended sediment contents, as well as with coal gasification wastewater which contained matrix organics at 10(6)-fold higher concentrations than the target aromatic hydrocarbons, Good agreement was obtained between a 45-min SPME and methylene chloride extraction for the determination of PAH concentrations in creosote-contaminated water, demonstrating that SPME is a useful technique for the rapid determination of hydrocarbons in complex water matrices.
引用
收藏
页码:144 / 155
页数:12
相关论文
共 17 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   ANALYSIS OF SUBSTITUTED BENZENE COMPOUNDS IN GROUNDWATER USING SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
MOTLAGH, S ;
LIM, M ;
POTTER, DW ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (05) :979-983
[3]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[4]  
BLEVINS DD, 1994, LC GC-MAG SEP SCI, V12, P12
[5]  
BOYDBOLAND AA, 1994, ENVIRON SCI TECHNOL, V28, pA569, DOI 10.1021/es00062a715
[6]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[7]   PERFORMANCE OF THE GOULDEN LARGE-SAMPLE EXTRACTOR IN MULTICLASS PESTICIDE ISOLATION AND PRECONCENTRATION FROM STREAM WATER [J].
FOSTER, GD ;
FOREMAN, WT ;
GATES, PM .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (09) :1618-1622
[8]   SORPTION OF BENZO[A]PYRENE AND PHENANTHRENE ON SUSPENDED HARBOR SEDIMENT AS A FUNCTION OF SUSPENDED SEDIMENT CONCENTRATION AND SALINITY - A LABORATORY STUDY USING THE COSOLVENT PARTITION-COEFFICIENT [J].
HEGEMAN, WJM ;
VANDERWEIJDEN, CH ;
LOCH, JPG .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (02) :363-371
[9]  
HO JS, 1995, J CHROMATOGR SCI, V33, P1
[10]  
LANGENFELD JJ, IN PRESS J CHROMATOG