Maximum likelihood estimation of signal amplitude and noise variance from MR data

被引:225
作者
Sijbers, J
den Dekker, AJ
机构
[1] Univ Antwerp, Vis Lab, Dept Phys, B-2020 Antwerp, Belgium
[2] Delft Univ Technol, Delft Ctr Syst & Control, Delft, Netherlands
关键词
D O I
10.1002/mrm.10728
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
In MRI, the raw data, which are acquired in spatial frequency space, are intrinsically complex valued and corrupted by Gaussian-distributed noise. After applying an inverse Fourier transform, the data remain complex valued and Gaussian distributed. If the signal amplitude is to be estimated, one has two options. It can be estimated directly from the complex valued data set, or one can first perform a magnitude operation on this data set, which changes the distribution of the data from Gaussian to Rician, and estimate the signal amplitude from the obtained magnitude image. Similarly, the noise variance can be estimated from both the complex and magnitude data sets. This article addresses the question whether it is better to use complex valued data or magnitude data for the estimation of these parameters using the maximum likelihood method. As a performance criterion, the mean-squared error (MSE) is used. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:586 / 594
页数:9
相关论文
共 21 条
[1]
[Anonymous], 1922, Philosophical Transactions of the Royal Society of London A, DOI [10.1098/rsta.1922.0009, DOI 10.1098/RSTA.1922.0009]
[2]
Uniform-penalty inversion of multiexponential decay data -: II.: Data spacing, T2 data, systematic data errors, and diagnostics [J].
Borgia, GC ;
Brown, RJS ;
Fantazzini, P .
JOURNAL OF MAGNETIC RESONANCE, 2000, 147 (02) :273-285
[3]
Callaghan P.T., 1995, PRINCIPLES NUCL MAGN
[4]
Compartmental study of T1 and T2 in rat brain and trigeminal nerve in vivo [J].
Does, MD ;
Gore, JC .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :274-283
[5]
Theory of statistical estimation. [J].
Fisher, RA .
PROCEEDINGS OF THE CAMBRIDGE PHILOSOPHICAL SOCIETY, 1925, 22 :700-725
[6]
Karlsen OT, 1999, MAGN RESON MED, V41, P614, DOI 10.1002/(SICI)1522-2594(199903)41:3<614::AID-MRM26>3.0.CO
[7]
2-1
[8]
AN UNBIASED SIGNAL-TO-NOISE RATIO MEASURE FOR MAGNETIC-RESONANCE IMAGES [J].
MCGIBNEY, G ;
SMITH, MR .
MEDICAL PHYSICS, 1993, 20 (04) :1077-1078
[9]
THE USE OF POWER IMAGES TO PERFORM QUANTITATIVE-ANALYSIS ON LOW SNR MR-IMAGES [J].
MILLER, AJ ;
JOSEPH, PM .
MAGNETIC RESONANCE IMAGING, 1993, 11 (07) :1051-1056
[10]
Wavelet-based Rician noise removal for magnetic resonance imaging [J].
Nowak, RD .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1999, 8 (10) :1408-1419