Practical and Efficient Strategy for Evaluating Oral Absolute Bioavailability with an Intravenous Microdose of a Stable Isotopically-Labeled Drug Using a Selected Reaction Monitoring Mass Spectrometry Assay

被引:36
作者
Jiang, Hao [1 ]
Zeng, Jianing [1 ]
Li, Wenying [2 ]
Bifano, Marc [3 ]
Gu, Huidong [1 ]
Titsch, Craig [1 ]
Easter, John [4 ]
Burrell, Richard [4 ]
Kandoussi, Hamza [1 ]
Aubry, Anne-Francoise [1 ]
Arnold, Mark E. [1 ]
机构
[1] Bristol Myers Squibb Co, Bioanalyt Sci Analyt & Bioanalyt Sci, Princeton, NJ 08540 USA
[2] Bristol Myers Squibb Co, Biotransformat Pharmaceut Candidate Optimizat, Princeton, NJ USA
[3] Bristol Myers Squibb Co, Clin Pharmacol Drug Metab & Clin Pharmacol, Princeton, NJ USA
[4] Bristol Myers Squibb Co, Discovery Chem Synth, Wallingford, CT 06492 USA
关键词
LIQUID-CHROMATOGRAPHY; ISOTOPE DISTRIBUTIONS; NS5A INHIBITOR; PHARMACOKINETICS; QUANTIFICATION; BIOANALYSIS; METABOLITES; TOOL;
D O I
10.1021/ac3024558
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A strategy of using selected reaction monitoring (SRM) mass spectrometry for evaluating oral absolute bioavailability with concurrent intravenous (IV) microdosing a stable isotopically labeled (SIL) drug was developed and validated. First, the isotopic contribution to SRM (ICSRM) of the proposed SIL drug and SIL internal standard (IS) was theoretically calculated to guide their chemical synthesis. Second, the lack of an isotope effect on drug exposure was evaluated in a monkey study by IV dosing a mixture of the SIL and the unlabeled drugs. Third, after the SIL drug (100 mu g) was concurrently IV dosed to humans, at T-max of an oral therapeutic dose of the unlabeled drug, both drugs in plasma specimens were simultaneously quantified by a sensitive and accurate SRM assay. This strategy significantly improves bioanalytical data quality and saves time, costs, and resources by avoiding a traditional absolute bioavailability study or the newer approach of microdoses of a radio-microtracer measured by accelerator mass spectrometry.
引用
收藏
页码:10031 / 10037
页数:7
相关论文
共 24 条
[1]
[Anonymous], 2006, BIOTECHNOL LAW REP, DOI DOI 10.1126/scitranslmed.aai7786
[2]
Barker J, 1999, RAPID COMMUN MASS SP, V13, P285, DOI 10.1002/(SICI)1097-0231(19990228)13:4<285::AID-RCM469>3.3.CO
[3]
2-I
[4]
Small Molecule Quantification by Liquid Chromatography-Mass Spectrometry for Metabolites of Drugs and Drug Candidates [J].
Dahal, Upendra P. ;
Jones, Jeffrey P. ;
Davis, John A. ;
Rock, Dan A. .
DRUG METABOLISM AND DISPOSITION, 2011, 39 (12) :2355-2360
[5]
Ultrasensitive Quantification of Serum Vitamin D Metabolites Using Selective Solid-Phase Extraction Coupled to Microflow Liquid Chromatography and Isotope-Dilution Mass Spectrometry [J].
Duan, Xiaotao ;
Weinstock-Guttman, Bianca ;
Wang, Hao ;
Bang, Eunjin ;
Li, Jun ;
Ramanathan, Murali ;
Qu, Jun .
ANALYTICAL CHEMISTRY, 2010, 82 (06) :2488-2497
[6]
Use of an oral/intravenous dual-label stable-isotope protocol to determine folic acid bioavailability from fortified cereal grain foods in women [J].
Finglas, PM ;
Witthöft, CM ;
Vahteristo, L ;
Wright, AJA ;
Southon, S ;
Mellon, FA ;
Ridge, B ;
Maunder, P .
JOURNAL OF NUTRITION, 2002, 132 (05) :936-939
[7]
Precision and Accuracy in the Quantitative Analysis of Biological Samples by Accelerator Mass Spectrometry: Application in Microdose Absolute Bioavailability Studies [J].
Gao, Lan ;
Li, Jing ;
Kasserra, Claudia ;
Song, Qi ;
Aromand, Ali ;
Hesk, David ;
Chowdhury, Swapan K. .
ANALYTICAL CHEMISTRY, 2011, 83 (14) :5607-5616
[8]
Chemical genetics strategy identifies an HCV NS5A inhibitor with a potent clinical effect [J].
Gao, Min ;
Nettles, Richard E. ;
Belema, Makonen ;
Snyder, Lawrence B. ;
Nguyen, Van N. ;
Fridell, Robert A. ;
Serrano-Wu, Michael H. ;
Langley, David R. ;
Sun, Jin-Hua ;
O'Boyle, Donald R. ;
Lemm, Julie A. ;
Wang, Chunfu ;
Knipe, Jay O. ;
Chien, Caly ;
Colonno, Richard J. ;
Grasela, Dennis M. ;
Meanwell, Nicholas A. ;
Hamann, Lawrence G. .
NATURE, 2010, 465 (7294) :96-U108
[9]
Accelerator mass spectrometry in pharmaceutical research and development - A new ultrasensitive analytical method of isotope measurement [J].
Garner, RC .
CURRENT DRUG METABOLISM, 2000, 1 (02) :205-213
[10]
Calculation and Mitigation of Isotopic Interferences in Liquid Chromatography-Mass Spectrometry/Mass Spectrometry Assays and Its Application in Supporting Microdose Absolute Bioavailability Studies [J].
Gu, Huidong ;
Wang, Jian ;
Aubry, Anne-Francoise ;
Jiang, Hao ;
Zeng, Jianing ;
Easter, John ;
Wang, Jun-sheng ;
Dockens, Randy ;
Bifano, Marc ;
Burrell, Richard ;
Arnold, Mark E. .
ANALYTICAL CHEMISTRY, 2012, 84 (11) :4844-4850