Serial magnetic resonance imaging evaluation of a bioabsorbable interference screw and the adjacent bone

被引:35
作者
Lajtai, G
Humer, K
Aitzetmüller, G
Unger, F
Noszian, I
Orthner, E
机构
[1] AKH Wels, Dept Traumatol, A-4600 Wels, Austria
[2] AKH Wels, Dept Radiol 2, A-4600 Wels, Austria
关键词
bioabsorbable; copolymer; 85/15; D; L lactide glycolide; MRI; ACL reconstruction; patellar tendon graft;
D O I
10.1053/ar.1999.v15.015048
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this prospective study was to review, using expanded clinical assessment tools, the initial use of a bioabsorbable interference screw (copolymer 85/15 D, L lactide/glycolide) in anterior cruciate ligament (ACL) reconstruction at the Wels Hospital, Austria. The study enlisted 32 patients of whom 28 were available for follow-up at minimum of 2.5 years. Since the implant material was new and the screw would not show on plain film radiographs, the clinical assessment was expanded beyond the usual historical and physical findings. The evaluation included opportunistic knee joint aspiration and repeat magnetic resonance imaging (MRI) studies to investigate the longevity of the implant and potential adverse effects of this new bioabsorbable material. The knee joint aspirations showed no infection. Serial MRIs showed the physical presence of the screw to remain intact for 4 months and disappear in 6 months. The MRIs showed minimal collection of edema around the bone tunnels that resolved by 12 months. There were no symptoms or adverse clinical result correlated with the MRI evidence of edema. There was temporary bone tunnel expansion. The clinical results were good. The OAK-score (Orthopadische Arbeitsgruppe Knie) showed 89.5 % excellent and good results, 7% fair results and 3.5 % poor results. The average score was 90.7 points (range, 63 to 100 points). The knee joint stability measured with the KT-1000 arthrometer showed 93% to have a 3-mm or less difference compared with the unoperated knee. This bioabsorbable interference screw appeared safe and effective for fixation of bone blocks during ACL reconstruction while producing no occult infection or adverse clinical response during the degradation process.
引用
收藏
页码:481 / 488
页数:8
相关论文
共 39 条
[1]
LONG-TERM STUDY OF ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION FOR CHRONIC INSTABILITY USING THE CENTRAL 1/3 PATELLAR TENDON AND A LATERAL EXTRAARTICULAR TENODESIS [J].
AGLIETTI, P ;
BUZZI, R ;
DANDRIA, S ;
ZACCHEROTTI, G .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (01) :38-45
[2]
PREOPERATIVE INSTRUMENTED TESTING OF ANTERIOR AND POSTERIOR KNEE LAXITY [J].
ANDERSON, AF ;
LIPSCOMB, AB .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (03) :387-392
[3]
ARNOCZKY SP, 1994, SCI EXH AM AC ORTH S
[4]
ARTHROSCOPY-ASSISTED ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING PATELLAR TENDON SUBSTITUTION - 2-YEAR TO 4-YEAR FOLLOW-YP RESULTS [J].
BACH, BR ;
JONES, GT ;
SWEET, FA ;
HAGER, CA .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (06) :758-767
[5]
BACH BR, 1989, AM J KNEE SURG, V2, P76
[6]
BALCH OK, UNPUB ANAL INTRA OSS
[7]
THE IN-VIVO HISTOLOGY OF AN ABSORBABLE SUTURE ANCHOR - A PRELIMINARY-REPORT [J].
BARBER, FA ;
DECK, MA .
ARTHROSCOPY, 1995, 11 (01) :77-81
[8]
BOSTMAN O, 1990, INT ORTHOP, V14, P1
[9]
BIODEGRADABLE INTERNAL-FIXATION FOR MALLEOLAR FRACTURES - A PROSPECTIVE RANDOMIZED TRIAL [J].
BOSTMAN, O ;
VAINIONPAA, S ;
HIRVENSALO, E ;
MAKELA, A ;
VIHTONEN, K ;
TORMALA, P ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04) :615-619
[10]
FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596