Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum

被引:61
作者
Martins, TB
Pasi, BM
Litwin, CM
Hill, HR
机构
[1] ARUP, Inst Clin & Expt Pathol, Salt Lake City, UT 84108 USA
[2] Univ Utah, Sch Med, Dept Pathol Pediat & Med, Salt Lake City, UT USA
关键词
D O I
10.1128/CDLI.11.2.325-329.2004
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
While modern immunoassays provide sensitive and specific means for the quantitation of cytokines in biological fluids, heterophile antibodies are still a well-recognized cause of interference in the measurement of cytokines in these assays. We have developed a multiplexed fluorescent microsphere immunoassay for the simultaneous quantification of 10 cytokines in only 75 mul of serum. During the development of this multiplexed assay, the amount of assay interference due to heterophile antibodies was also determined, and methods for detecting heterophile interference and minimizing its effect were incorporated into the assay. Heterophile antibodies resulted in significantly elevated cytokine values compared to those of normal blood bank samples. These falsely elevated values, and thus the components of the assay the heterophile antibodies were binding to, were identified through the use of internal controls. This information was then used to design assay-specific blockers and absorbents that were shown to significantly reduce falsely elevated cytokine values while not affecting the standard and control values. The fluorescent multiplexed microsphere-based immunoassay can be used to quantitate multiple cytokines from a single sample and should be a useful tool in furthering our understanding of the role of cytokines in disease processes.
引用
收藏
页码:325 / 329
页数:5
相关论文
共 20 条
[1]   Measurement of cytokines in clinical samples using immunoassays: Problems and pitfalls [J].
Banks, RE .
CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2000, 37 (02) :131-182
[2]   Cytokine assays in human sera and tissues [J].
Bienvenu, JAD ;
Monneret, G ;
Gutowski, MC ;
Fabien, N .
TOXICOLOGY, 1998, 129 (01) :55-61
[3]  
BOERMAN OC, 1990, CLIN CHEM, V36, P888
[4]  
BOSCATO LM, 1986, CLIN CHEM, V32, P1491
[5]  
BOSCATO LM, 1988, CLIN CHEM, V34, P27
[6]  
Fulton RJ, 1997, CLIN CHEM, V43, P1749
[7]   FACTORS AFFECTING THE MEASUREMENT OF CYTOKINES IN BIOLOGICAL-FLUIDS - IMPLICATIONS FOR THEIR CLINICAL MEASUREMENT [J].
HENEY, D ;
WHICHER, JT .
ANNALS OF CLINICAL BIOCHEMISTRY, 1995, 32 :358-368
[8]   The influence of naturally occurring heterophilic anti-immunoglobulin antibodies on direct measurement of serum proteins using sandwich ELISAs [J].
Hennig, C ;
Rink, L ;
Fagin, U ;
Jabs, WJ ;
Kirchner, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 235 (1-2) :71-80
[9]   ELISA DETECTION OF IL-1-BETA IN HUMAN SERA NEEDS INDEPENDENT CONFIRMATION - FALSE POSITIVES IN HOSPITALIZED-PATIENTS [J].
HERZYK, DJ ;
WEWERS, MD .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (01) :139-142
[10]  
Kellar KL, 2001, CYTOMETRY, V45, P27, DOI 10.1002/1097-0320(20010901)45:1<27::AID-CYTO1141>3.0.CO