Electrochemiluminescence detection of dichlorvos pesticide in luminol-CTAB medium

被引:26
作者
Chen, Xiao-mei
Lin, Zhi-jie
Cai, Zhi-min
Chen, Xi [1 ,2 ]
Wang, Xiao-ru
机构
[1] Xiamen Univ, Dept Chem, Coll Chem & Chem Engn, Xiamen 361005, Peoples R China
[2] Xiamen Univ, State Key Lab Marine Environm Sci, Xiamen 361005, Peoples R China
关键词
electrochemiluminescence; dichlorvos pesticide; luminol; glassy carbon electrode;
D O I
10.1016/j.talanta.2008.05.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, novel electrochemiluminescence (ECL) method for the detection of dichlorvos pesticide (DDVP) with high sensitivity was discovered. Detection was carried out in a static ECL system, in which a glassy carbon electrode was selected as the working electrode. ECL parameters, including the concentrations of cetyrltrimethylammonium bromide and luminol. the solution pH, and the scan rate of the applied potential, were optimized. Under these optimal conditions, the linear response of ECL-emission versus DDVP concentration was valid in the range 5-8000 ng/L (r(2) = 0.9982) with a relative standard deviation of 4.3% at 2000 ng/L(n = 10), yielding a detection limit (S/N = 3) of 0.42 ng/L. The ECL emission was caused by a radical reaction process, in which the dissolved oxygen in the luminol solution reacted with the DDVP and generated free radicals. The free radicals reacted with the luminol anion and yielded the luminol radical. The approach presented was successfully applied to the determination of DDVP residues in vegetable samples. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1083 / 1087
页数:5
相关论文
共 31 条
[1]   Pesticide analysis in herbal infusions by solid-phase microextraction and gas chromatography with atomic emission detection [J].
Campillo, Natalia ;
Penalver, Rosa ;
Hernandez-Cordoba, Manuel .
TALANTA, 2007, 71 (03) :1417-1423
[2]   Analysis of pesticide residues in matrices with high lipid contents by membrane separation coupled on-line to a high-performance liquid chromatography system [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Paniagua-Marcos, PH ;
Hernández-Méndez, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :427-439
[3]  
CATER WG, 2007, HUM EXP TOXICOL, V26, P347
[4]   Determination of dichlorvos by on-line microwave-assisted extraction coupled to headspace solid-phase microextraction and gas chromatography-electron-capture detection [J].
Chen, YI ;
Su, YS ;
Jen, JF .
JOURNAL OF CHROMATOGRAPHY A, 2002, 976 (1-2) :349-355
[5]  
Cho Y, 1997, CHEM PHARM BULL, V45, P737, DOI 10.1248/cpb.45.737
[6]   Multichannel electrochemiluminescence of luminol in neutral and alkaline aqueous solutions on a gold nanoparticle self-assembled electrode [J].
Cui, H ;
Xu, Y ;
Zhang, ZF .
ANALYTICAL CHEMISTRY, 2004, 76 (14) :4002-4010
[7]   Electrochemiluminescence of luminol in alkaline solution at a paraffin-impregnated graphite electrode [J].
Cui, H ;
Zou, GZ ;
Lin, XQ .
ANALYTICAL CHEMISTRY, 2003, 75 (02) :324-331
[8]  
Del Carlo M, 2006, J FOOD PROTECT, V69, P1406
[9]   Fate of postharvest-applied dichlorvos in stored and processed dates [J].
El-Behissy, EY ;
King, RD ;
Ahmed, MM ;
Youssef, AM .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (03) :1239-1245
[10]   Mediated bioelectrocatalytic determination of organophosphorus pesticides with a tyrosinase-based oxygen biosensor [J].
Everett, WR ;
Rechnitz, GA .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :807-810