Leaching of diethylhexyl phthalate from polyvinyl chloride bags into intravenous etoposide solution

被引:22
作者
Demoré, B
Vigneron, J
Perrin, A
Hoffman, MA
Hoffman, M
机构
[1] Ctr Hosp Univ Nancy, F-54511 Vandoeuvre Les Nancy, France
[2] Ctr Hosp Univ Nancy, Pharm Hop Cent, Nancy, France
关键词
diethylhexyl phthalate (DEHP); etoposide; HPLC; polyvinyl chloride (PVC) bags;
D O I
10.1046/j.1365-2710.2002.00395.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective: To compare the release of diethylhexyl phthalate (DEHP) from polyvinyl chloride (PVC) bags from four different manufacturers into intravenous etoposide solutions. Method Etoposide solutions, 0.4 mg/mL, containing the vehicle polysorbate 80 were prepared in 5% dextrose or 0.9% sodium chloride injection PVC bags and stored at room temperature for 24 h. DEHP content was analysed by high-performance liquid chromatography. Results Substantial amounts of DEHP (up to 20 mug/mL at room temperature) leached into the etoposide solutions. However, no significant differences were found in the amounts of DEHP leached into the etoposide infusion solutions prepared using either 5% dextrose or 0.9% sodium chloride injection and stored in the four different containers. Conclusion To minimize patient exposure o DEHP, etoposide solutions should ideally be stored in a glass or polyolefin container.
引用
收藏
页码:139 / 142
页数:4
相关论文
共 16 条
  • [1] DIETHYLHEXYL PHTHALATE AS A FACTOR IN BLOOD-TRANSFUSION AND HEMODIALYSIS
    BAKER, RWR
    [J]. TOXICOLOGY, 1978, 9 (04) : 319 - 329
  • [2] STABILITY AND COMPATIBILITY OF ETOPOSIDE IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION IN 3 CONTAINERS
    BARTHES, DMC
    ROCHARD, EB
    POULIQUEN, IJ
    RABOUAN, SM
    COURTOIS, PY
    [J]. AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1994, 51 (21): : 2706 - 2709
  • [3] PLATELETS STORED FOR 6 DAYS IN A POLYOLEFIN CONTAINER IN A SYNTHETIC MEDIUM WITH MINIMAL PLASMA CARRY-OVER
    BOOMGAARD, MN
    GOUWEROK, CWN
    DEKORTE, D
    LOOS, JA
    [J]. VOX SANGUINIS, 1994, 66 (01) : 18 - 24
  • [4] LEACHING OF PLASTICIZERS FROM AND SURFACE CHARACTERIZATION OF PVC BLOOD-PLATELET BAGS
    CHAWLA, AS
    HINBERG, I
    [J]. BIOMATERIALS ARTIFICIAL CELLS AND IMMOBILIZATION BIOTECHNOLOGY, 1991, 19 (04): : 761 - 783
  • [5] RAPID-DETERMINATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DI-2-ETHYLHEXYL PHTHALATE IN PLASMA STORED IN PLASTIC BAGS
    DINE, T
    LUYCKX, M
    CAZIN, M
    BRUNET, C
    CAZIN, JC
    GOUDALIEZ, F
    [J]. BIOMEDICAL CHROMATOGRAPHY, 1991, 5 (02) : 94 - 97
  • [6] DOWNIE G, 1985, BR J PARENT THER, V11, P142
  • [7] LEACHING OF DIETHYLHEXYL PHTHALATE FROM PVC BAGS INTO INTRAVENOUS TENIPOSIDE SOLUTION
    FAOUZI, MA
    DINE, T
    LUYCKX, M
    GRESSIER, B
    GOUDALIEZ, F
    MALLEVAIS, ML
    BRUNET, C
    CAZIN, M
    CAZIN, JC
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1994, 105 (01) : 89 - 93
  • [8] HAMON M, 1987, STP PHARM, V3, P33
  • [9] HIGHER ATP LEVEL AND REDUCED GLUCOSE CONSUMPTION OF RED-CELLS STORED IN PVC BAGS COMPARED TO GLASS BOTTLES
    HEGEDUS, E
    RACZ, Z
    [J]. VOX SANGUINIS, 1987, 53 (02) : 83 - 83
  • [10] MIGRATION OF A PHTHALATE ESTER PLASTICIZER FROM POLYVINYL-CHLORIDE BLOOD BAGS INTO STORED HUMAN BLOOD AND ITS LOCALIZATION IN HUMAN TISSUES
    JAEGER, RJ
    RUBIN, RJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1972, 287 (22) : 1114 - &