Follow-up radiographs of the cervical spine after anterior fusion with titanium intervertebral disc

被引:5
作者
Biederer, J
Hutzelmann, A
Rama, B
Heller, M
机构
[1] Christian Albrechts Univ Kiel Klinikum, Radiol Diagnost Klin, Kiel, Germany
[2] Paracelsus Klin Osnabruck, Neurochirurg Klin, Osnabruck, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1999年 / 171卷 / 02期
关键词
anterior cervical discectomy; radiculopathy; myelopathy; anterior cervical fusion; titanium implantat;
D O I
10.1055/s-1999-11086
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: We examined the postoperative changes of the cervical spine after treatment of cervical nerve root compression with anterior cervical discectomy and fusion with a new titanium intervertebral disc. Patients and Methods: 37 patients were examined prior to, as well as 4 days, 6 weeks, and 7 months after surgery. Lateral view X-rays and functional imaging were used to evaluate posture and mobility of the cervical spine, the position of the implants, and the reactions of adjacent bone structures. Results: Implantation of the titanium disc led to post-operative distraction of the intervertebral space and slight lordosis. Within the first 6 months a slight loss of distraction and re-kyphosis due to impression of the implants into the vertebral end-plates were found in all patients. We noted partial infractions into the vertebral end-plates in 10/42 segments and slight mobility of the implants in 14/42 segments. Both groups of patients showed reactive spondylosis and local symptoms due to loosening of the implants. The pain subsided after onset of bone bridging and stable fixation of the loosened discs. Conclusions: The titanium intervertebral disc provides initial distraction of the fusioned segments with partial recurrence of kyphosis during the subsequent course. Loosening of the implants with local symptoms can be evaluated with follow-up X-rays and functional imaging.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 26 条
[1]
RADIOLOGIC LONG-TERM RESULTS AFTER CERVICAL VERTEBRAL INTERBODY FUSION WITH POLY(METHYL METHACRYLATE (PMMA) [J].
BOKER, DK ;
SCHULTHEISS, R ;
PROBST, EM .
NEUROSURGICAL REVIEW, 1989, 12 (03) :217-221
[2]
CLOWARD R B, 1962, Clin Neurosurg, V8, P93
[3]
THE ANTERIOR APPROACH FOR REMOVAL OF RUPTURED CERVICAL DISKS [J].
CLOWARD, RB .
JOURNAL OF NEUROSURGERY, 1958, 15 (06) :602-617
[4]
Dunsker S B, 1977, Clin Neurosurg, V24, P516
[5]
FUNCTIONAL RADIOGRAPHIC DIAGNOSIS OF THE CERVICAL-SPINE - FLEXION EXTENSION [J].
DVORAK, J ;
FROEHLICH, D ;
PENNING, L ;
BAUMGARTNER, H ;
PANJABI, MM .
SPINE, 1988, 13 (07) :748-755
[6]
RADIOLOGIC EVALUATION OF SURGICAL CERVICAL-SPINE FUSION [J].
FOLEY, MJ ;
LEE, C ;
CALENOFF, L ;
HENDRIX, RW ;
CERULLO, LJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (01) :79-89
[7]
GOYMANN V, 1981, Z ORTHOP GRENZGEB, V119, P734
[8]
GROTE W, 1981, Z ORTHOP GRENZGEB, V119, P728
[9]
GROTE W, 1993, NEUROCHIRURGIE, V2, P191
[10]
HALLEN LG, 1966, ACTA ORTHOP SCAND, V37, P1