Evaluation of Lunar Prodigy dual-energy X-ray absorptiometry for assessing body composition in healthy persons and patients by comparison with the criterion 4-component model

被引:157
作者
Williams, JE
Wells, JCK
Wilson, CM
Haroun, D
Lucas, A
Fewtrell, MS
机构
[1] Inst Child Hlth, MRC, Childhood Nutr Res Ctr, London WC1N 1EH, England
[2] Great Ormond St Hosp Children, Dept Radiol, London WC1N 3JH, England
关键词
body composition; fat mass; fat-free mass; dual-energy X-ray absorptiometry; DXA; obesity; clinical practice;
D O I
10.1093/ajcn/83.5.1047
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: Dual-energy X-ray absorptiometry (DXA) is widely used to assess body composition in research and clinical practice. Several studies have evaluated its accuracy in healthy persons; however, little attention has been directed to the same issue in patients. Objective: The objective was to compare the accuracy of the Lunar Prodigy DXA for body-composition analysis with that of the reference 4-component (4C) model in healthy subjects and in patients with 1 of 3 disease states. Design: A total of 215 subjects aged 5.0-21.3 y (n = 122 healthy nonobese subjects, n = 55 obese patients, n = 26 cystic fibrosis patients, and n = 12 patients with glycogen storage disease). Fat mass (FM), fat-free mass (FFM), and weight were measured by DXA and the 4C model. Results: The accuracy of DXA-measured body-composition outcomes differed significantly between groups. Factors independently predicting bias in weight, FM, FFM, and percentage body fat in multivariate models included age, sex, size, and disease state. Biases in FFM were not mirrored by equivalent opposite biases in FM because of confounding biases in weight. Conclusions: The bias of DXA varies according to the sex, size, fatness, and disease state of the subjects, which indicates that DXA is unreliable for patient case-control studies and for longitudinal studies of persons who undergo significant changes in nutritional status between measurements. A single correction factor cannot adjust for inconsistent biases.
引用
收藏
页码:1047 / 1054
页数:8
相关论文
共 40 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Validity of methods of body composition assessment in young and older men and women [J].
Clasey, JL ;
Kanaley, JA ;
Wideman, L ;
Heymsfield, SB ;
Teates, CD ;
Gutgesell, ME ;
Thorner, MO ;
Hartman, ML ;
Weltman, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (05) :1728-1738
[3]  
Cole TJ, 2000, STAT MED, V19, P3109, DOI 10.1002/1097-0258(20001130)19:22<3109::AID-SIM558>3.0.CO
[4]  
2-F
[5]   BODY-MASS INDEX REFERENCE CURVES FOR THE UK, 1990 [J].
COLE, TJ ;
FREEMAN, JV ;
PREECE, MA .
ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 73 (01) :25-29
[6]   Sympercents:: symmetric percentage differences on the 100 loge scale simplify the presentation of log transformed data -: by T.J.!Cole, Statistics in Medicine 2000; 19:3109-3125. [J].
Cole, TJ ;
Kryakin, YV .
STATISTICS IN MEDICINE, 2002, 21 (15) :2287-2290
[7]   Whole body air displacement plethysmography compared with hydrodensitometry for body composition analysis [J].
Dewit, O ;
Fuller, NJ ;
Fewtrell, MS ;
Elia, M ;
Wells, JCK .
ARCHIVES OF DISEASE IN CHILDHOOD, 2000, 82 (02) :159-164
[8]   Body-composition assessment via air-displacement plethysmography in adults and children: a review [J].
Fields, DA ;
Goran, MI ;
McCrory, MA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2002, 75 (03) :453-467
[9]  
Freeman JV, 1990, ARCH DIS CHILD, V1995, P17
[10]   4-COMPONENT MODEL FOR THE ASSESSMENT OF BODY-COMPOSITION IN HUMANS - COMPARISON WITH ALTERNATIVE METHODS, AND EVALUATION OF THE DENSITY AND HYDRATION OF FAT-FREE MASS [J].
FULLER, NJ ;
JEBB, SA ;
LASKEY, MA ;
COWARD, WA ;
ELIA, M .
CLINICAL SCIENCE, 1992, 82 (06) :687-693