MR navigator-echo monitoring of temporal changes in diaphragm position: Implications for MR coronary angiography

被引:138
作者
Taylor, AM
Jhooti, P
Wiesmann, F
Keegan, J
Firmin, DN
Pennell, DJ
机构
[1] Magnetic Resonance Unit, Royal Brompton Hospital, Sydney Street
关键词
magnetic resonance coronary angiography; navigator echo; diaphragm monitoring;
D O I
10.1002/jmri.1880070404
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Temporal changes in respiration could influence navigator-echo (NE)-gated MR coronary angiography (MRCA), but systematic investigation of the effects of such variations sind how to limit them has not been performed, We addressed these issues by studying the influence of time in the magnet on diaphragm position and respiratory patterns using NE diaphragm monitoring in volunteers and a phantom model, NE diaphragm monitoring was performed at .5 T in 10 subjects over a total period of 35 minutes. The end-expiratory position was sustained for longer (1.1 vs .4 seconds, P < .001) and with greater position stability (SD 1.9 vs 5.9 mm, P = .01) than the end-inspiratory position, Drift of the end-expiratory position occurred over time, causing a fall in scan efficiency (44-28%, P = .01), Up-drift of the end-expiratory position was most: common, Loss of scan efficiency was worse with up-drift because of loss of the end-expiratory pause from the NE window (up-drift 10% mm(-1), down-drift 7% mm(-1), both P = .03). Scan efficiency also was reduced during sleep (to a nadir of 0%), secondary to loss of the end-expiratory pause, periodic breathing with oscillating end-expiratory position, and periods of apnea, The phantom model used actual diaphragm traces to evaluate the artifact resulting from diaphragm motion during acquisition, Artifact was considerably reduced by NE adaptive motion correction compared with NE gating alone (ghosting ratio 2.0 vs 2.8, P < .01), Artifact also was significantly reduced with up-drift if scan efficiency was maintained above 35% (P = .05), For optimal NE-gated MRCA, the following features are important: the NE window should be placed around the end-expiratory position; subjects should not sleep; scan efficiency should be monitored and the NE window should be repositioned if scan efficiency falls below 35%; and adaptive motion correction should be used.
引用
收藏
页码:629 / 636
页数:8
相关论文
共 16 条
  • [1] BULOW K, 1963, ACTA PHYSIOL SCAND, V59, P7
  • [2] DANIAS PG, 1996, P INT SOC MAGN RES M, P177
  • [3] ULTRASOUND QUANTITATION OF RESPIRATORY ORGAN MOTION IN THE UPPER ABDOMEN
    DAVIES, SC
    HILL, AL
    HOLMES, RB
    HALLIWELL, M
    JACKSON, PC
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803) : 1096 - 1102
  • [4] FRIEDMAN J, 1989, J NUCL MED, V30, P1718
  • [5] DIAPHRAGMATIC MOTION - FAST GRADIENT-RECALLED-ECHO MR-IMAGING IN HEALTHY-SUBJECTS
    GIERADA, DS
    CURTIN, JJ
    ERICKSON, SJ
    PROST, RW
    STRANDT, JA
    GOODMAN, LR
    [J]. RADIOLOGY, 1995, 194 (03) : 879 - 884
  • [6] RESPIRATORY KINEMATICS OF THE UPPER ABDOMINAL ORGANS - A QUANTITATIVE STUDY
    KORIN, HW
    EHMAN, RL
    RIEDERER, SJ
    FELMLEE, JP
    GRIMM, RC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) : 172 - 178
  • [7] A MONITORING, FEEDBACK, AND TRIGGERING SYSTEM FOR REPRODUCIBLE BREATH-HOLD MR-IMAGING
    LIU, YL
    RIEDERER, SJ
    ROSSMAN, PJ
    GRIMM, RC
    DEBBINS, JP
    EHMAN, RL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) : 507 - 511
  • [8] FAT-SUPPRESSED BREATH-HOLD MAGNETIC-RESONANCE CORONARY ANGIOGRAPHY
    MANNING, WJ
    LI, W
    BOYLE, NG
    EDELMAN, RR
    [J]. CIRCULATION, 1993, 87 (01) : 94 - 104
  • [9] MCCONNELL MV, 1996, P 4 ANN M INT SOC MA, P450
  • [10] PENNELL DJ, 1993, BRIT HEART J, V70, P315