Multivariate calibration modelling using electrochemical/inductively coupled plasma mass spectrometry data for trace elements in ultrahigh quality water and humic acid matrices

被引:6
作者
Donachie, A [1 ]
Walmsley, AD [1 ]
Haswell, SJ [1 ]
机构
[1] UNIV HULL,SCH CHEM,CCPAS,HULL,PQ HU6 7RX,CANADA
来源
ANALYTICAL COMMUNICATIONS | 1996年 / 33卷 / 09期
关键词
D O I
10.1039/ac9963300293
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Robust multivariate calibration is described for the determination of trace metals in water matrices, A multivariate calibration model containing electrochemical and ICP-MS concentration data for Zn, Cu, Cd and Pb mixtures in the 0.5-50 mu g l(-1) range was constructed using the partial least squares (PLS) method, Fifty solutions were prepared in ultrahigh quality (UHQ) water to which humic acid was added to simulate interferents. A second data set consisting of similar elemental combinations was prepared in a UHQ water matrix only. The electrochemical data was collected using anodic stripping voltammetry with ICP-MS providing independent quantitative data, All experimental work was carried out in replicate to account for variations in the ambient experimental conditions and to aid the identification of outliers, The training data set used for the calibration model was transformed prior to modelling using two separate data pre-treatment techniques, The first technique scaled the raw data using the mean of one method whilst the second used the same technique with 10% random noise added to the raw data. These two pre-treatment techniques are compared and contrasted, The calibration model using the second pre-treatment technique gave the most accurate concentration predictions for eight unknown test solutions which consisted of four solutions from either matrix, These predictions were all within a 10% relative standard error of the actual concentrations.
引用
收藏
页码:293 / 296
页数:4
相关论文
共 9 条
[1]   SENSORS AND SAMPLE PREPARATION IN STRIPPING VOLTAMMETRY [J].
BRAININA, KZ .
ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) :146-153
[2]   ON-SITE MONITORING OF TOTAL COPPER BY ANODIC-STRIPPING VOLTAMMETRY, DURING ALGICIDE DOSING OF A RESERVOIR [J].
CHOW, CWK ;
DAVEY, DE ;
MULCAHY, DE .
ANALYTICAL LETTERS, 1994, 27 (01) :113-130
[3]   CHEMOMETRIC INVESTIGATIONS ON THE DIFFERENTIATED EVALUATION OF ELEMENT TRACE ANALYSIS IN RIVER WATERS [J].
EINAX, J ;
GEISS, S .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (1-2) :14-17
[4]  
JAGNER D, 1993, ELECTROANALYSIS NY, V6, P201
[5]   DYNAMIC PLS MODELING FOR PROCESS-CONTROL [J].
KASPAR, MH ;
RAY, WH .
CHEMICAL ENGINEERING SCIENCE, 1993, 48 (20) :3447-3461
[6]  
ROBUSTE JR, 1993, ANALUSIS, V21, P299
[7]   THE EFFECTS OF COPPER-ZINC AND COPPER-CADMIUM INTERMETALLIC COMPOUNDS IN DIFFERENT SYSTEMS USED FOR ANODIC-STRIPPING VOLTAMMETRY [J].
WISE, JA ;
ROSTON, DA ;
HEINEMAN, WR .
ANALYTICA CHIMICA ACTA, 1983, 154 (NOV) :95-104
[8]  
WOLD S, 1983, LECT NOTES MATH, V973, P286
[9]  
WOLD S, 1984, ANALUSIS, V12, P477