Fluorometric determination of ammonia in sea and estuarine waters by direct segmented flow analysis

被引:263
作者
Kerouel, R
Aminot, A
机构
[1] IFREMER-Brest, 29280 Plouzané
关键词
ammonia; sea water; fluorometry; automated analysis;
D O I
10.1016/S0304-4203(97)00040-6
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A direct automated method for routine determination of ammonia in sea and estuarine waters has been developed using segmented flow analysis. The method, based on the reaction of ammonia with orthophtaldialdehyde (OPA) and sulfite, is easy to use, sensitive and highly reproducible. The combination of reagents makes it highly selective, thus eliminating the need for the gas diffusion cell commonly used to remove amino acid interference. Results on kinetics, on reagent composition and light effects and on pH and salinity changes are presented. The salt-effect does not exceed 3% in the 0-35 salinity range. Interference from primary amines is < 0.5%. Among the naturally occurring inorganic species tested, only sulfide presents a significant, depressive effect. The method can be used in oligotrophic areas (detection limit 1.5 nmol l(-1)); specific recommendations are provided accordingly. Repeatability of 0.01 mu mol l(-1) was achieved in marine samples with ammonia concentrations ranging from 0.5 to 5 mu mol l(-1). Using on-line dilution. ammonia determination can be performed up to 250 mu mol l(-1) and salt effect becomes negligible. Comparison of the present CPA-method with the indophenol blue method yielded fully comparable results. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:265 / 275
页数:11
相关论文
共 26 条
[1]   AUTOMATIC-DETERMINATION OF UREA IN SEA-WATER - A SENSIBLE METHOD USING DIACETYLMONOXIME [J].
AMINOT, A ;
KEROUEL, R .
CANADIAN JOURNAL OF FISHERIES AND AQUATIC SCIENCES, 1982, 39 (01) :174-183
[2]   Determination of ammonia in seawater by the indophenol-blue method: Evaluation of the ICES NUTS I/C 5 questionnaire [J].
Aminot, A ;
Kirkwood, DS ;
Kerouel, R .
MARINE CHEMISTRY, 1997, 56 (1-2) :59-75
[3]  
AMINOT A, 1995, 213 ICES COOP
[4]  
AMINOT A, 1995, 5 ICES INT EX NUTR S, V213, P41
[6]   CHARACTERIZATION AND REDUCTION OF INTERFERENCES IN FLOW-INJECTION ANALYSIS FOR THE IN-SITU DETERMINATION OF NITRATE AND NITRITE IN SEA-WATER [J].
DANIEL, A ;
BIROT, D ;
LEHAITRE, M ;
PONCIN, J .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :413-424
[7]   SORPTION OF AMMONIUM BY GLASS FRITS AND FILTERS - IMPLICATIONS FOR ANALYSES OF BRACKISH AND FRESHWATER [J].
EATON, AD ;
GRANT, V .
LIMNOLOGY AND OCEANOGRAPHY, 1979, 24 (02) :397-399
[8]   DETERMINATION OF SUBMICROMOLAR CONCENTRATIONS OF AMMONIA IN NATURAL-WATERS BY A STANDARD ADDITION METHOD USING A GAS-SENSING ELECTRODE [J].
GARSIDE, C ;
HULL, G ;
MURRAY, S .
LIMNOLOGY AND OCEANOGRAPHY, 1978, 23 (05) :1073-1076
[9]  
GENFA Z, 1989, Analytical Chemistry, V61, P408, DOI 10.1021/ac00180a006
[10]   ANALYSIS OF AMMONIA AND METHYLAMINES IN NATURAL-WATERS BY FLOW-INJECTION GAS-DIFFUSION COUPLED TO ION CHROMATOGRAPHY [J].
GIBB, SW ;
MANTOURA, RFC ;
LISS, PS .
ANALYTICA CHIMICA ACTA, 1995, 316 (03) :291-304