Preparation of blood-compatible hollow fibers from a polymer alloy composed of polysulfone and 2-methacryloyloxyethyl phosphorylcholine polymer

被引:76
作者
Hasegawa, T
Iwasaki, Y
Ishihara, K
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Mat Engn, Bunkyo Ku, Tokyo 1138656, Japan
[2] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo 1010062, Japan
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2002年 / 63卷 / 03期
关键词
blood compatibility; hollow fiber; hemodialysis; polysulfone; 2-methacryloyloxyethyl; phosphorylcholine polymer; polymer alloy; nonfouling property;
D O I
10.1002/jbm.10210
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood-compatible hollow fibers were successfully prepared from a polymer alloy composed of polysulfone (PSf) and the 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer. To improve the hydrophillicity, fouling-resistance characteristics, and blood compatibility of the PSf hollow fiber in a hemodialyzer, an MPC polymer that can be blended with PSf was synthesized in order to prepare the polymer alloy (PSf/MPC polymer). The contents of the MPC polymer blended in the PSf were 7 and 15 wt%. The PSf/MPC polymer hollow fiber could be prepared by both wet and dry-wet processing methods. The hollow fiber took an asymmetric structure, that is, the hollow-fiber membrane had a dense skin layer on the porous sponge-like structure. The mechanical strength was higher than that of conventional PSf hollow fibers for hemodialysis. The surface characterization of the PSf/MPC polymer hollow fiber by x-ray photoelectron spectroscopy revealed that the MPC units were concentrated at the surface. The permeability for solutes through the PSf/MPC polymer hollow fibers was measured for 4 h. The permeabilities of both a low-molecular-weight compound and protein were greater than those of the PSf hollow fibers. The amount of adsorbed protein was lower on the PSf/MPC polymer hollow fiber when compared to that of the PSf hollow fiber. Moreover, platelet adhesion was also effectively inhibited on the PSf/MPC polymer hollow fiber. Based on these results, the addition of the MPC polymer to the PSf is a very useful method to improve the functions and blood compatibility of the hollow fiber. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:333 / 341
页数:9
相关论文
共 28 条
[1]  
Boyd RF, 1998, BIOTECHNOL BIOENG, V59, P451, DOI 10.1002/(SICI)1097-0290(19980820)59:4<451::AID-BIT8>3.0.CO
[2]  
2-F
[3]  
CAMPBELL EJ, 1994, ASAIO J, V40, P853
[4]   Preparation and performance of protein-adsorption-resistant asymmetric porous membrane composed of polysulfone/phospholipid polymer blend [J].
Hasegawa, T ;
Iwasaki, Y ;
Ishihara, K .
BIOMATERIALS, 2001, 22 (03) :243-251
[5]   Clinical performance of a new high-flux synthetic membrane [J].
Hoenich, NA ;
Stamp, S .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 36 (02) :345-352
[6]  
Irena G, 1999, EUR POLYM J, V35, P1419
[7]  
IRENA G, 2000, EUR POLYM J, V36, P1563
[8]  
Ishihara K, 1998, J BIOMED MATER RES, V39, P323, DOI 10.1002/(SICI)1097-4636(199802)39:2<323::AID-JBM21>3.0.CO
[9]  
2-C
[10]   Modification of polysulfone with phospholipid polymer for improvement of the blood compatibility. Part 1. Surface characterization [J].
Ishihara, K ;
Fukumoto, K ;
Iwasaki, Y ;
Nakabayashi, N .
BIOMATERIALS, 1999, 20 (17) :1545-1551