Quality assurance in screening for sight-threatening diabetic retinopathy

被引:35
作者
Pandit, RJ
Taylor, R
机构
[1] Royal Victoria Infirm, Diabet Unit, Dept Ophthalmol, Newcastle Upon Tyne NE1 4LP, Tyne & Wear, England
[2] Royal Victoria Infirm, Dept Med, Newcastle Upon Tyne NE1 4LP, Tyne & Wear, England
关键词
quality assurance; screening; diabetic retinopathy;
D O I
10.1046/j.1464-5491.2002.00722.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims There is a need for continuous evaluation of screening services for diabetic retinopathy against agreed performance standards. We describe a quality assurance programme implemented in Newcastle in January 1999 and report on outcomes at 18 months. Methods Annual retinal screening is performed using combined retinal photography and direct ophthatmoscopy in two streams. Diabetologisrs perform screening in the Hospital Screening Programme, which serves patients whose diabetes is managed in specialist clinics, and trained retinal screeners perform screening in the District Screening Programme, which serves patients whose diabetes is managed in the community. Reference standard examination of dilated fundoscopy with a slit-lamp and condensing lens was performed by an ophthalmologist at periodic sessions on consecutive patients attending for screening. Results Six hundred and nine (6.4%) of 9468 patients screened underwent reference standard examination. The sensitivity and specificity of detection of sight-threatening diabetic retinopathy (STDR) was 82.5% and 98%, respectively, for the Hospital Screening Programme; 85.7% and 95.7%, respectively, for the District Screening Programme; and 83.3% and 96.8% for both services combined. One hundred and ten (18.1%) of 609 patients audited were referred to ophthalmology as a result of screening, and this led to 16 patients (2.6%) receiving laser photocoagulation for STDR. Reference standard examination identified a further four patients (0.7%) who required laser photocoagulation. Conclusions Preliminary data indicate that satisfactory performance standards are being achieved. The National Service Framework for Diabetes requires that all units institute quality assurance for retinal screening, and we report the practical implementation of this in one district.
引用
收藏
页码:285 / 291
页数:7
相关论文
共 28 条
[1]  
Agardh E, 1996, ACTA OPHTHALMOL SCAN, V74, P166
[2]   THE 5-YEAR INCIDENCE OF BLINDNESS AFTER INTRODUCING A SCREENING-PROGRAM FOR EARLY DETECTION OF TREATABLE DIABETIC-RETINOPATHY [J].
AGARDH, E ;
AGARDH, CD ;
HANSSONLUNDBLAD, C .
DIABETIC MEDICINE, 1993, 10 (06) :555-559
[3]  
[Anonymous], 1991, Ophthalmology, V98, P786
[4]  
[Anonymous], 1991, Diabet Med, V8, P263
[5]  
BLACKLUND LB, 1997, DIABETIC MED, V14, P732
[6]   Preservation of sight in diabetes: developing a national risk reduction programme [J].
Garvican, L ;
Clowes, J ;
Gillow, T .
DIABETIC MEDICINE, 2000, 17 (09) :627-634
[7]   AN OPTICAL PRACTICE-BASED DIABETIC EYE SCREENING-PROGRAM [J].
GATLING, W ;
HOWIE, AJ ;
HILL, RD .
DIABETIC MEDICINE, 1995, 12 (06) :531-536
[8]   SENSITIVITY AND SPECIFICITY OF PHOTOGRAPHY AND DIRECT OPHTHALMOSCOPY IN SCREENING FOR SIGHT THREATENING EYE DISEASE - THE LIVERPOOL DIABETIC EYE STUDY [J].
HARDING, SP ;
BROADBENT, DM ;
NEOH, C ;
WHITE, MC ;
VORA, J .
BMJ-BRITISH MEDICAL JOURNAL, 1995, 311 (7013) :1131-1135
[9]  
Henricsson M, 1996, ACTA OPHTHALMOL SCAN, V74, P533
[10]   A REPORT ON THE USE OF TECHNICIAN OPHTHALMOSCOPY COMBINED WITH THE USE OF THE CANON NONMYDRIATIC CAMERA IN SCREENING FOR DIABETIC-RETINOPATHY IN THE COMMUNITY [J].
JACOB, J ;
STEAD, J ;
SYKES, J ;
TAYLOR, D ;
TOOKE, JE .
DIABETIC MEDICINE, 1995, 12 (05) :419-425