Quantitative spatially resolved measurements of mass transfer through laryngeal cartilage

被引:55
作者
Macpherson, JV
OHare, D
Unwin, PR
Winlove, CP
机构
[1] UNIV WARWICK, DEPT CHEM, COVENTRY CV4 7AL, W MIDLANDS, ENGLAND
[2] UNIV BRIGHTON, DEPT PHARM, BRIGHTON BN2 4GJ, E SUSSEX, ENGLAND
[3] UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED, PHYSIOL FLOW STUDIES GRP, LONDON SW7 2BZ, ENGLAND
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1016/S0006-3495(97)78306-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The scanning electrochemical microscope (SECM) is a scanned probe microscope that uses the response of a mobile ultramicroelectrode (UME) tip to determine the reactivity, topography, and mass transport characteristics of interfaces with high spatial resolution. SECM strategies for measuring the rates of solute diffusion and convection through samples of cartilage, using amperometric UMEs, are outlined. The methods are used to determine the diffusion coefficients of oxygen and ruthenium(III) hexamine [Ru(NH3)(6)(3+)] in laryngeal cartilage. The diffusion coefficient of oxygen in cartilage is found to be similar to 50% of that in aqueous electrolyte solution, assuming a partition coefficient of unity for oxygen between cartilage and aqueous solution. In contrast, diffusion of Ru(NH3)(6)(3+) within the cartilage sample cannot be detected on the SECM timescale, suggesting a diffusion coefficient at least two orders of magnitude lower than that in solution, given a measured partition coefficient for Ru(NH3)(6)(3+) between cartilage and aqueous solution, K-p = [Ru(NH3)(6)(3+)](cartilage)/[Ru(NH3)(6)(3+)](solution) = 3.4 +/- 0.1. Rates of Ru(NH3)(6)(3+) osmotically driven convective transport across cartilage samples are imaged at high spatial resolution by monitoring the current response of a scanning UME, with an osmotic pressure of similar to 0.75 atm across the slice, A model is outlined that enables the current response to be related to the local flux. By determining the topography of the sample from the current response with no applied osmotic pressure, local transport rates can be correlated with topographical features of the sample surface, at much higher spatial resolution than has previously been achieved.
引用
收藏
页码:2771 / 2781
页数:11
相关论文
共 52 条
[1]  
ALLHANDS RV, 1984, CORNELL VET, V74, P111
[2]  
Bard A.J., 1994, ELECTROANAL CHEM, V18, A., P243
[3]   SCANNING ELECTROCHEMICAL MICROSCOPY - INTRODUCTION AND PRINCIPLES [J].
BARD, AJ ;
FAN, FRF ;
KWAK, J ;
LEV, O .
ANALYTICAL CHEMISTRY, 1989, 61 (02) :132-138
[4]   CHEMICAL IMAGING OF SURFACES WITH THE SCANNING ELECTROCHEMICAL MICROSCOPE [J].
BARD, AJ ;
FAN, FRF ;
PIERCE, DT ;
UNWIN, PR ;
WIPF, DO ;
ZHOU, FM .
SCIENCE, 1991, 254 (5028) :68-74
[5]  
BARD AJ, 1992, AIP CONF PROC, V241, P235
[6]   A study of the effect of ultrasound on mass transport to a microelectrode [J].
Birkin, PR ;
SilvaMartinez, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 416 (1-2) :127-138
[7]  
BLOEBAUM RD, 1980, J ANAT, V131, P333
[8]   DIFFUSION OF SMALL SOLUTES IN CARTILAGE AS MEASURED BY NUCLEAR-MAGNETIC-RESONANCE (NMR) SPECTROSCOPY AND IMAGING [J].
BURSTEIN, D ;
GRAY, ML ;
HARTMAN, AL ;
GIPE, R ;
FOY, BD .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1993, 11 (04) :465-478
[9]  
Carleton H. M., 1980, Carleton's histological technique
[10]  
FAN FR, 1996, SCIENCE, V270, P1849