Separation of tocopherol isomers using capillary electrochromatography:: Comparison of monomeric and polymeric C30 stationary phases

被引:35
作者
Henry, CW [1 ]
Fortier, CA [1 ]
Warner, IM [1 ]
机构
[1] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70893 USA
关键词
D O I
10.1021/ac011018a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The comparison of tocopherol isomer separation achieved using different stationary-phase alkyl chain lengths (i.e., C-18 VS C-30) and modes of alkyl phase attachment to the silica-based supports (i.e., polymeric vs monomeric synthesis) using capillary electrochromatography (CEC) has been demonstrated. The smaller alkyl chain does not exhibit the shape selectivity needed to resolve all of the tocopherol isomers. Conversely, both polymeric and monomeric C-30 phases show increased tocopherol isomer selectivity. Changing the elutropic strength of the mobile phase had dramatic effects on the selectivity, with small additions of water to a methanol mobile phase yielding the best selectivity. The complete baseline separation of the tocopherol isomers was achieved using the monomerically bound C-30 stationary phase and a methanol/water mobile phase. The differences in stationary-phase selectivity were examined using a NIST standard reference material for determining column selectivity in LC. The results indicated that the monomeric C-30 actually had "intermediate" phase characteristics (i.e., high phase loading, end capping, etc). This new CEC-based separation was also used to separate the tocopherols in a vitamin E supplement sample.
引用
收藏
页码:6077 / 6082
页数:6
相关论文
共 27 条
[1]   EVALUATION OF BONDED PHASES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN EFFLUENT WATERS [J].
AMOS, R .
JOURNAL OF CHROMATOGRAPHY, 1981, 204 (JAN) :469-478
[2]   MICROEMULSION ELECTROKINETIC CHROMATOGRAPHY WITH DIFFERENT ORGANIC MODIFIERS - SEPARATION OF WATER-SOLUBLE AND LIPID-SOLUBLE VITAMINS [J].
BOSO, RL ;
BELLINI, MS ;
MIKSIK, I ;
DEYL, Z .
JOURNAL OF CHROMATOGRAPHY A, 1995, 709 (01) :11-19
[3]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[4]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[5]  
DITTMANN MM, 1995, LC GC, V13, P8006
[6]   Separation of geometrical carotenoid isomers in biological extracts using a polymeric C-30 column in reversed-phase liquid chromatography [J].
Emenhiser, C ;
Simunovic, N ;
Sander, LC ;
Schwartz, SJ .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1996, 44 (12) :3887-3893
[7]   CAPABILITY OF A POLYMERIC C-30 STATIONARY-PHASE TO RESOLVE CIS-TRANS CAROTENOID ISOMERS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
EMENHISER, C ;
SANDER, LC ;
SCHWARTZ, SJ .
JOURNAL OF CHROMATOGRAPHY A, 1995, 707 (02) :205-216
[8]  
GERSTER H, 1993, INT J VITAM NUTR RES, V63, P93
[9]   Simultaneous determination of low plasma concentrations of retinol and tocopherols in preterm infants by a high-performance liquid chromatographic micromethod [J].
Gobel, Y ;
Schaffer, C ;
Koletzko, B .
JOURNAL OF CHROMATOGRAPHY B, 1997, 688 (01) :57-62
[10]   Determination of alpha-, gamma(+beta)-, and delta-tocopherols in a variety of liver tissues by reverse-phase high pressure liquid chromatography [J].
Koprivnjak, JF ;
Lum, KR ;
Sisak, MM ;
Saborowski, R .
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY B-BIOCHEMISTRY & MOLECULAR BIOLOGY, 1996, 113 (01) :143-148