Air-cooled cold trap channel integrated in a microfluidic device for monitoring airborne BTEX with an improved detection limit

被引:31
作者
Ueno, Y [1 ]
Horiuchi, T [1 ]
Niwa, O [1 ]
机构
[1] NTT Corp, Lifestyle & Environm Technol Labs, Atsugi, Kanagawa 2430198, Japan
关键词
D O I
10.1021/ac0110810
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We integrated an air-cooled cold trap (CT) channel in a microfluidic device for monitoring airborne benzene, toluene, ethylbenzene, and xylene (BTEX) gases and demonstrated its effect on improving the detection limit of the microfluidic device. The device consists of concentration and detection cells formed of 3 x 1 cm Pyrex plates. We first introduced a sample gas into the concentration cell, and the gas was adsorbed onto an adsorbent in the channel. We then raised the temperature using a thin-film heater and introduced the desorbed gas into the detection cell. To prevent dilution of the gas before detection, we propose an improvement to the concentration cell structure that involves the integration of the CT channel. We examined the CT effect by comparing three types of concentration cell with different channel structures. We found that we could detect a gas concentration about 2 orders of magnitude lower than in our previous work by optimizing the channel structure and integrating a CT channel. As an example of BTEX detection, we obtained a 0.05 ppm detection limit for toluene gas with a sampling time of 30 min.
引用
收藏
页码:1712 / 1717
页数:6
相关论文
共 15 条
[1]  
[Anonymous], 1993, GAS CHROMATOGRAPHIC
[2]  
[Anonymous], EPA453R99007
[3]  
ETELATALO EK, 1997, J CHROMATOGR A, V787, P205
[4]  
*EUR ENV AG, 2000, ENV ISS SER, V12
[5]   THE NEAR ULTRAVIOLET ABSORPTION SPECTRUM OF TOLUENE VAPOR [J].
GINSBURG, N ;
ROBERTSON, WW ;
MATSEN, FA .
JOURNAL OF CHEMICAL PHYSICS, 1946, 14 (09) :511-517
[6]  
*GOV JAP MIN ENV, 1997, ENV QUAL STAND JAP A
[7]   AUTOMATED IN-SITU GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF PPT LEVEL VOLATILE ORGANIC TRACE GASES USING MULTISTAGE SOLID-ADSORBENT TRAPPING [J].
HELMIG, D ;
GREENBERG, JP .
JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (01) :123-132
[8]   EFFECT OF OPERATING PARAMETERS IN PURGE-AND-TRAP GC-MS OF POLAR AND NONPOLAR ORGANIC-COMPOUNDS [J].
KOSTIAINEN, R .
CHROMATOGRAPHIA, 1994, 38 (11-12) :709-714
[9]   POSSIBILITIES OF ANALYZING INDOOR AIR BY GAS-CHROMATOGRAPHY USING RETENTION INDEX MONITORING [J].
MATTINEN, ML ;
SANDELL, E ;
SAARELA, K .
TOXICOLOGICAL AND ENVIRONMENTAL CHEMISTRY, 1993, 40 (1-4) :133-142
[10]   Technique for monitoring toxic VOCs in air: Sorbent preconcentration, closed-cycle cooler cryofocusing and GC/MS analysis [J].
Oliver, KD ;
Adams, JR ;
Daughtrey, EH ;
Mcclenny, WA ;
Yoong, MJ ;
Pardee, MA ;
Almasi, EB ;
Kirshen, NA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (06) :1939-1945