Flow detection of nucleic acids at a conducting polymer-modified electrode

被引:48
作者
Wang, J [1 ]
Jiang, M [1 ]
Mukherjee, B [1 ]
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
关键词
D O I
10.1021/ac9903205
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new protocol for electrochemical detection of nucleic acids, based on polypyrrole (PPy)-coated electrodes, is demonstrated using flow injection analysis. The conducting polymer detection scheme offers a fast, sensitive, universal detection of oligonucleotides, DNA, and RNA. The response is attributed to the adsorption/desorption of the nucleic acids onto the Pgi film during the passage of the sample plug over the coated electrode. The influence of various experimental parameters of the film preparation and the electrochemical detection has been investigated. Optimal performance has been achieved using the nitrate film dopant, a detection potential of -0.15 V (vs Ag/AgCl), and a flow rate of 0.6 mL/min. Good linearity and reproducibility (RSD = 2.1%) are observed, along with very low detection limits (e.g., 6.1 x 10(-16) mol of dsDNA in the 20-mu L samples). Compared to common detectors based on the electroactivity of DNA, the conducting polymer detection scheme is not limited to purine-containing nucleic acids or to a strongly alkaline media and is less susceptible to interferences from easily oxidizable species (e.g., ascorbic acid). The attractive behavior of the PPy now detector holds great promise for monitoring nucleic acids in other now systems, microscale separations, and on-chip platforms.
引用
收藏
页码:4095 / 4099
页数:5
相关论文
共 21 条
[1]  
[Anonymous], 1994, ANAL ELECTROCHEMISTR
[2]   CHEMICALLY MODIFIED ELECTRODES IN LIQUID-CHROMATOGRAPHY DETECTION - A REVIEW [J].
BALDWIN, RP ;
THOMSEN, KN .
TALANTA, 1991, 38 (01) :1-16
[3]   ELECTROCONDUCTING CONJUGATED POLYMERS - NEW SENSITIVE MATRICES TO BUILD UP CHEMICAL OR ELECTROCHEMICAL SENSORS - A REVIEW [J].
BIDAN, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :45-56
[4]   ELECTROANALYSIS WITH ELECTRODES MODIFIED BY INORGANIC FILMS [J].
COX, JA ;
JAWORSKI, RK ;
KULESZA, PJ .
ELECTROANALYSIS, 1991, 3 (09) :869-877
[5]  
Lu W, 1998, ELECTROANAL, V10, P1101, DOI 10.1002/(SICI)1521-4109(199811)10:16<1101::AID-ELAN1101>3.0.CO
[6]  
2-6
[7]   A miniature analytical instrument for nucleic acids based on micromachined silicon reaction chambers [J].
Northrup, MA ;
Benett, B ;
Hadley, D ;
Landre, P ;
Lehew, S ;
Richards, J ;
Stratton, P .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :918-922
[8]   From polarography of DNA to microanalysis with nucleic acid-modified electrodes [J].
Palecek, E .
ELECTROANALYSIS, 1996, 8 (01) :7-14
[9]   DNA bound to polypyrrole films: high-resolution imaging, DNA binding kinetics and internal migration [J].
Pande, R ;
Ruben, GC ;
Lim, JO ;
Tripathy, S ;
Marx, KA .
BIOMATERIALS, 1998, 19 (18) :1657-1667
[10]   ELECTRONIC GAS AND ODOR DETECTORS THAT MIMIC CHEMORECEPTION IN ANIMALS [J].
PERSAUD, KC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1992, 11 (02) :61-67