Development of a simple and highly sensitive enzyme immunoassay for hepatitis C virus core antigen

被引:176
作者
Aoyagi, K
Ohue, C
Iida, K
Kimura, T
Tanaka, E
Kiyosawa, K
Yagi, S
机构
[1] Tonen Corp, Div Diagnost, Ohi, Saitama 3568505, Japan
[2] Shinshu Univ, Sch Med, Dept Internal Med 2, Nagano 3908621, Japan
关键词
D O I
10.1128/JCM.37.6.1802-1808.1999
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A highly sensitive enzyme immunoassay (EIA) for the hepatitis C virus (HCV) core antigen (HCVcAg) was developed, and its performance was compared with that of the AMPLICOR HCV test (Roche Molecular Systems). The developed one-step pretreatment method, 30-min incubation of the specimen with a solution containing three different types of detergents (Triton X-100, 3-[(3-cholamidopropyl)-dimethylammonio]-1-propanesulfonate [CHAPS], and sodium dodecyl sulfate), does not require any special device. Because the interfering anti-core antibody in the sample was sufficiently inactivated by the pretreatment, HCVcAg in the sample could be detected. The immunoreactivity on gel filtration was shifted from void fractions to those corresponding to the molecular mass range from 20 to 25 kDa, which is equal to the estimated molecular mass of HCVcAg, after the pretreatment. By the recovery test with HCVcAg-positive serum, the recovery rate was 93.5 to 106.5%. There was no interference with the EIA by anticoagulants or blood components in the serum. When the cutoff value was tentatively set at 0.5 mU/ml based on the distribution of healthy subjects' sera, the sera of all healthy subjects (n = 125) and patients with hepatitis B (n = 50) were negative. HCVcAg was detected in sera from 57 of 73 individuals (78.1%) with anti-HCV antibody. Similarly, WCV RNA was detected in sera from 59 individuals (80.8%) with the AMPLICOR HCV as the qualitative test (AMPLICOR HCV test) and in sera from 54 individuals (74.0%) by the AMPLICOR HCV Monitor as the quantitative test (AMPLICOR Monitor test). Concentrations of HCVcAg and HCV RNA (measured by the AMPLICOR Monitor test) correlated significantly (r = 0.8, P < 0.001). On seroconversion panels, HCVcAg was detected during the early stage of infection, when anti-HCV antibodies had not been produced. This assay for HCVcAg is simpler than assays for HCV RNA based on gene technology and shows specificity and sensitivity equivalent to those of the AMPLICOR HCV test.
引用
收藏
页码:1802 / 1808
页数:7
相关论文
共 43 条
  • [1] AOYAGI K, UNPUB
  • [2] BEUTLER E, 1990, BIOTECHNIQUES, V9, P166
  • [3] SEQUENCE-ANALYSIS OF THE CORE GENE OF 14 HEPATITIS-C VIRUS GENOTYPES
    BUKH, J
    PURCELL, RH
    MILLER, RH
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (17) : 8239 - 8243
  • [4] Declining value of alanine aminotransferase in screening of blood donors to prevent posttransfusion hepatitis B and C virus infection
    Busch, MP
    Korelitz, JJ
    Kleinman, SH
    Lee, SR
    AuBuchon, JP
    Schreiber, GB
    Williams, AE
    Ownby, HE
    Waxman, DA
    Hutching, S
    Murphy, EL
    Gilcher, RO
    Smith, JW
    Thomson, RA
    Nemo, GJ
    Zuck, TF
    [J]. TRANSFUSION, 1995, 35 (11) : 903 - 910
  • [5] ISOLATION OF A CDNA CLONE DERIVED FROM A BLOOD-BORNE NON-A, NON-B VIRAL-HEPATITIS GENOME
    CHOO, QL
    KUO, G
    WEINER, AJ
    OVERBY, LR
    BRADLEY, DW
    HOUGHTON, M
    [J]. SCIENCE, 1989, 244 (4902) : 359 - 362
  • [6] ASSOCIATION OF HEPATITIS-C VIRUS-PARTICLES WITH IMMUNOGLOBULIN - A MECHANISM FOR PERSISTENT INFECTION
    CHOO, SH
    SO, HS
    CHO, JM
    RYU, WS
    [J]. JOURNAL OF GENERAL VIROLOGY, 1995, 76 : 2337 - 2341
  • [7] DAVIS GL, 1994, HEPATOLOGY, V19, P1337, DOI 10.1002/hep.1840190603
  • [8] Impact of various handling and storage conditions on quantitative detection of hepatitis C virus RNA
    Halfon, P
    Khiri, H
    Gerolami, V
    Bourliere, M
    Feryn, JM
    Reynier, P
    Gauthier, A
    Cartouzou, G
    [J]. JOURNAL OF HEPATOLOGY, 1996, 25 (03) : 307 - 311
  • [9] Comparison of plasma virus loads among individuals infected with hepatitis C virus (HCV) genotypes 1, 2, and 3 by Quantiplex HCV RNA assay versions 1 and 2, Roche monitor assay, and an in-house limiting dilution method
    Hawkins, A
    Davidson, F
    Simmonds, P
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (01) : 187 - 192
  • [10] GENE-MAPPING OF THE PUTATIVE STRUCTURAL REGION OF THE HEPATITIS-C VIRUS GENOME BY INVITRO PROCESSING ANALYSIS
    HIJIKATA, M
    KATO, N
    OOTSUYAMA, Y
    NAKAGAWA, M
    SHIMOTOHNO, K
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (13) : 5547 - 5551