Microwave-assisted extraction of pyrethroid insecticides from semi permeable membrane devices (SPMDs) used to indoor air monitoring

被引:30
作者
Esteve-Turrillas, FA [1 ]
Pastor, A [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, Edifici Jeroni Munoz, E-46100 Valencia, Spain
关键词
semi permeable membrane device (SPMD); pyrethroid; residues; microwave-assisted extraction; indoor air; mass-mass spectrometry;
D O I
10.1016/j.aca.2005.12.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and environmentally friendly methodology was developed for the extraction of pyrethroid insecticides from semi permeable membrane devices (SPMDs), in which they were preconcentrated in gas phase. The method was based on gas chromatography mass-mass spectrometry determination after a microwave-assisted extraction, in front of the widely employed dialysis method. SPMDs were extracted twice with 30 mL hexane:acetone, irradiated with 250 W power output, until 90 degrees C in 10 min, this temperature being held for another 10 min. Clean-up of the extracts was performed by acetonitrile-hexane partitioning and solid-phase extraction (SPE) with a combined cartridge of 2 g basic-alumina, deactivated with 5% water, and 500 mg C-18. Pyrethroids investigated were Allethrin, Prallethrin, Tetramethrin, Bifenthrin, Phenothrin, lambda-Cyhalothrin, Permethrin, Cyfluthrin, Cypermethrin, Flucythrinate, Esfenvalerate, Fluvalinate and Deltamethrin. The main pyrethroid synergist compound, Pyperonyl Butoxide, was also studied. Limit of detection values ranging from 0.3 to 0.9 ng/SPMD and repeatability data, as relative standard deviation, from 2.9 to 9.4%, were achieved. Pyrethroid recoveries, for spiked SPMDs, with 100 ng of each one of the pyrethroids evaluated, were from 61 +/- 8 to 103 +/- 7% for microwave-assisted extraction, versus 54 +/- 4 to 104 +/- 3% for dialysis reference method. Substantial reduction of solvent consumed (from 400 to 60 mL) and analysis time (from 48 to 1 h) was achieved by using the developed procedure. High concentration levels of pyrethroid compounds, from 0.14 to 7.3 mu g/SPMD, were found in indoor air after 2 h of a standard application. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 127
页数:10
相关论文
共 27 条
[1]  
[Anonymous], ENV HLTH CRIT
[2]   A multi-residue method for characterization and determination of atmospheric pesticides measured at two French urban and rural sampling sites [J].
Baraud, L ;
Tessier, D ;
Aaron, JJ ;
Quisefit, JP ;
Pinart, J .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (7-8) :1148-1152
[3]   Field-based evaluation of semipermeable membrane devices (SPMDs) as passive air samplers of polyaromatic hydrocarbons (PAHs) [J].
Bartkow, ME ;
Huckins, JN ;
Müller, JF .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (35) :5983-5990
[4]  
Dean J., 1998, EXTRACTION METHODS E
[5]   Multiclass/multiresidue method for monitoring widely applied plant protecting agents in air during field dispersion work [J].
Demel, J ;
Buchberger, W ;
Malissa, H .
JOURNAL OF CHROMATOGRAPHY A, 2001, 931 (1-2) :107-117
[6]   Development of a gas chromatography-mass spectrometry method for the determination of household insecticides in indoor air [J].
Elflein, L ;
Berger-Preiss, E ;
Levsen, K ;
Wünsch, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) :147-157
[7]  
Eskilsson CS, 2000, J CHROMATOGR A, V902, P227
[8]   Microwave-assisted extraction of pyrethroid insecticides from soil [J].
Esteve-Turrillas, FA ;
Aman, CS ;
Pastor, A ;
de la Guardia, A .
ANALYTICA CHIMICA ACTA, 2004, 522 (01) :73-78
[9]   Screening method for pesticides in air by gas chromatography/tandem mass spectrometry [J].
Gonzalez, FJE ;
Granero, AM ;
Glass, CR ;
Frenich, AG ;
Vidal, JLM .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (05) :537-543
[10]   Chronic illness as a result of low-level exposure to synthetic pyrethroid insecticides: a review of the debate [J].
Kolaczinski, JH ;
Curtis, CF .
FOOD AND CHEMICAL TOXICOLOGY, 2004, 42 (05) :697-706