Effectiveness of a bioabsorbable conduit in the repair of peripheral nerve

被引:82
作者
Aldini, NN
Perego, G
Cella, GD
Maltarello, MC
Fini, M
Rocca, M
Giardino, R
机构
[1] UNIV BOLOGNA,CATTEDRA FISIOPATOL CHIRURG,BOLOGNA,ITALY
[2] IST RIC CODIVILLA PUTTI IOR,LAB BIOL CELLULARE & MICROSCOPIA ELETTRON,BOLOGNA,ITALY
[3] NOVAMONT SPA,NOVARA,ITALY
关键词
nerve repair; polylactic acid; biomaterials; microsurgery;
D O I
10.1016/0142-9612(96)84669-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new conduit made with a bioabsorbable copolymer, poly(L-lactide-co-6-caprolactone), was evaluated in an animal model as a guide for nerve regeneration. The conduit had an inner diameter of 1.3 mm and a wall thickness of 175 mu m. Segments of length 1.2 cm were interposed between the proximal and distal stumps of transected ischiatic nerves in Wistar rats, bridging a nerve gap of 1 cm. All of the procedure was performed under general anaesthesia using microsurgical techniques. Controls were performed at 1, 3 and 6 months and it was demonstrated that the conduit was still undamaged after 30 d. Progressive signs of degradation appeared at 90 and 180 d. Nerve regeneration in the lumen was effective as confirmed by histological and electron microscopical investigations. These preliminary results emphasize the interesting properties of the conduit with regard to the achievement of a neural prosthesis.
引用
收藏
页码:959 / 962
页数:4
相关论文
共 16 条
  • [1] ALDINI NN, 1993, ANN ITAL CHIR, V64, P717
  • [2] ALDINI NN, 1992, EUR SURG RES, V24, P39
  • [3] ALDINI NN, 1990, INT J ARTIF ORGANS, V13, P625
  • [4] A PROSPECTIVE CLINICAL-EVALUATION OF AUTOGENOUS VEIN GRAFTS USED AS A NERVE CONDUIT FOR DISTAL SENSORY NERVE DEFECTS OF 3 CM OR LESS
    CHIU, DTW
    STRAUCH, B
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 86 (05) : 928 - 934
  • [5] DELLON AL, 1989, MICROSURG, V10, P117
  • [6] NERVE REGENERATION THROUGH ARTIFICIAL TUBULAR IMPLANTS
    FIELDS, RD
    LEBEAU, JM
    LONGO, FM
    ELLISMAN, MH
    [J]. PROGRESS IN NEUROBIOLOGY, 1989, 33 (02) : 87 - +
  • [7] COMPARISON OF NERVE REGENERATION THROUGH DIFFERENT TYPES OF NEURAL PROSTHESES
    GIBSON, KL
    REMSON, L
    SMITH, A
    SATTERLEE, N
    STRAIN, GM
    DANILOFF, JK
    [J]. MICROSURGERY, 1991, 12 (02) : 80 - 85
  • [8] GIBSON KL, 1989, MICROSURG, V10, P125
  • [9] A COMPARISON OF SUTURE AND TUBULIZATION NERVE REPAIR TECHNIQUES IN A PRIMATE
    HENTZ, VR
    ROSEN, JM
    XIAO, SJ
    MCGILL, KC
    ABRAHAM, G
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (02): : 251 - 261
  • [10] 2-PLY BIODEGRADABLE NERVE GUIDE - BASIC ASPECTS OF DESIGN, CONSTRUCTION AND BIOLOGICAL PERFORMANCE
    HOPPEN, HJ
    LEENSLAG, JW
    PENNINGS, AJ
    VANDERLEI, B
    ROBINSON, PH
    [J]. BIOMATERIALS, 1990, 11 (04) : 286 - 290