Diastolic isthmus length and 'vertical' isthmus angulation identify patients with difficult catheter ablation of typical atrial flutter: a pre-procedural MRI study

被引:18
作者
Kirchhof, Paulus [1 ,2 ]
Oezguen, Murat [3 ]
Zellerhoff, Stephan
Moennig, Gerold
Eckardt, Lars
Wasmer, Kristina
Heindel, Walter [3 ]
Breithardt, Guenter [2 ]
Maintz, David [3 ]
机构
[1] Univ Klinikum Munster, Med Klin & Poliklin C, Dept Cardiol & Angiol, D-48129 Munster, Germany
[2] German Atrial Fibrillat Competence Network, Munster, Germany
[3] Univ Klinikum Munster, Inst Clin Radiol, D-48129 Munster, Germany
来源
EUROPACE | 2009年 / 11卷 / 01期
关键词
RADIOFREQUENCY ABLATION; CAVOTRICUSPID ISTHMUS; CONDUCTION; ANATOMY; TIP; FEASIBILITY; THERAPY; BLOCK; TIME;
D O I
10.1093/europace/eun308
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Catheter ablation of isthmus-dependent atrial flutter is technically demanding in some patients and extremely simple in others. The intervention targets a defined anatomical structure, the so-called cavotricuspid isthmus (CTI). We sought to characterize CTI anatomy in vivo in patients with difficult and simple catheter ablation of atrial flutter. Twenty-six patients were studied. Seven patients with difficult (n = 6) or extremely simple (n = 1) CTI ablation procedures were retrospectively selected from our catheter ablation database. Thereafter, we prospectively studied 19 patients undergoing CTI ablation in our department. We visualized CTI anatomy by ECG- and respiration-gated free precession 1.5 T cardiac magnetic resonance imaging (MRI). Magnetic resonance imaging was analysed for systolic and diastolic CTI length, the angle between the vena cava inferior and CTI, and pouch-like recesses. These parameters were compared between patients with difficult and simple procedures, split by the median number of energy applications. Patients with difficult procedures had a longer diastolic CTI length (diastolic isthmus length 20.3 +/- 1.8 mm) than those with simple procedures (diastolic isthmus length 16.6 +/- 1.7 mm, all data as mean +/- SEM, P < 0.05). Cavotricuspid isthmus angulation with respect to inferior vena cava was closer to 90 degrees in patients with difficult procedures (deviation from 90 degrees: 15 +/- 2 degrees) than those with simple procedures (deviation 23 +/- 4 degrees, P < 0.05). Systolic CTI length was not different between groups (32 +/- 2 mm in both groups, P > 0.2). Longer diastolic, but not systolic, CTI length and a rectangular angle between CTI and inferior vena cava render CTI catheter ablation difficult. Visualization of isthmus anatomy may help to guide difficult CTI ablation procedures.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 28 条
[1]   Radiofrequency catheter ablation of common atrial flutter - Significance of palpitations and quality-of-life evaluation in patients with proven isthmus block [J].
Anselme, F ;
Saoudi, N ;
Poty, H ;
Douillet, R ;
Cribier, A .
CIRCULATION, 1999, 99 (04) :534-540
[2]   Angiographic anatomy of the inferior right atrial isthmus in patients with and without history of common atrial flutter [J].
Cabrera, JA ;
Sanchez-Quintana, D ;
Ho, SY ;
Medina, A ;
Wanguemert, F ;
Gross, E ;
Grillo, J ;
Hernandez, E ;
Anderson, RH .
CIRCULATION, 1999, 99 (23) :3017-3023
[3]   VALIDATION OF DOUBLE-SPIKE ELECTROGRAMS AS MARKERS OF CONDUCTION DELAY OR BLOCK IN ATRIAL-FLUTTER [J].
COSIO, FG ;
ARRIBAS, F ;
BARBERO, JM ;
KALLMEYER, C ;
GOICOLEA, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (10) :775-780
[4]   Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus [J].
Da Costa, A ;
Faure, E ;
Thévenin, J ;
Messier, M ;
Bernard, S ;
Abdel, K ;
Robin, C ;
Romeyer, C ;
Isaaz, K .
CIRCULATION, 2004, 110 (09) :1030-1035
[5]   Comparison of the efficacy of cooled-tip and 8-mm-tip catheters for radiofrequency catheter ablation of the cavotricuspid isthmus:: A meta-analysis [J].
Da Costa, A ;
Cucherat, M ;
Pichon, N ;
Messier, M ;
Laporte, S ;
Roméyer-Bouchard, C ;
Mismetti, P ;
Lopez, M ;
Isaaz, K .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (10) :1081-1087
[6]   Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time [J].
Dickfeld, T ;
Calkins, H ;
Zviman, M ;
Kato, R ;
Meininger, G ;
Lickfett, L ;
Berger, R ;
Halperin, H ;
Solomon, SB .
CIRCULATION, 2003, 108 (19) :2407-2413
[7]   Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: a prospective randomized trial [J].
Earley, MJ ;
Showkathali, R ;
Alzetani, M ;
Kistler, PM ;
Gupta, D ;
Abrams, DJ ;
Horrocks, JA ;
Harris, SJ ;
Sporton, SC ;
Schilling, RJ .
EUROPEAN HEART JOURNAL, 2006, 27 (10) :1223-1229
[8]   Cardiac three-dimensional magnetic resonance imaging and fluoroscopy merging -: A new approach for electroanatomic mapping to assist catheter ablation [J].
Ector, J ;
De Buck, S ;
Adams, J ;
Dymarkowski, S ;
Bogaert, J ;
Maes, F ;
Heidbüchel, H .
CIRCULATION, 2005, 112 (24) :3769-3776
[9]   RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF HUMAN TYPE-1 ATRIAL-FLUTTER - IDENTIFICATION OF A CRITICAL ZONE IN THE REENTRANT CIRCUIT BY ENDOCARDIAL MAPPING TECHNIQUES [J].
FELD, GK ;
FLECK, RP ;
CHEN, PS ;
BOYCE, K ;
BAHNSON, TD ;
STEIN, JB ;
CALISI, CM ;
IBARRA, M .
CIRCULATION, 1992, 86 (04) :1233-1240
[10]   Radiofrequency catheter ablation of common atrial flutter in 200 patients [J].
Fischer, B ;
Jais, P ;
Shah, DP ;
Chouairi, S ;
Haissaguerre, M ;
Garrigues, S ;
Poquet, F ;
Gencel, L ;
Clementy, J ;
Marcus, FI .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (12) :1225-1233