Trace-level determination of pesticide residues using on-line solid-phase extraction-column liquid chromatography with atmospheric pressure ionization mass spectrometric and tandem mass spectrometric detection

被引:85
作者
Slobodnik, J
Hogenboom, AC
Vreuls, JJ
Rontree, JA
vanBaar, BLM
Niessen, WMA
Brinkman, UAT
机构
[1] FREE UNIV AMSTERDAM,DEPT ANALYT CHEM,NL-1081 HV AMSTERDAM,NETHERLANDS
[2] BIOTECH MS,VG ORGAN ANAL,FISONS INSTRUMENTS,ALTRINCHAM WA14 5RZ,CHESHIRE,ENGLAND
[3] FREE UNIV AMSTERDAM,DEPT ORGAN CHEM,NL-1081 HV AMSTERDAM,NETHERLANDS
关键词
mass spectrometry; trace analysis; tandem mass spectrometry; pesticides;
D O I
10.1016/0021-9673(96)00139-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Column liquid chromatography (LC) with pneumatically assisted electrospray (PA-ESP) or atmospheric pressure chemical ionization (APCI) followed by (tandem) mass spectrometry (MS or MS-MS) was used for the analysis of a test mixture of 17 pesticides. In order to achieve low-ng/l detection limits, solid-phase extraction (SPE) of a 100-ml aqueous sample on a small cartridge packed with a hydrophobic sorbent was used. The LC set-up was coupled on-line to the MS part of the system. The complete analysis was automated by means of a gradient controller and a Prospekt valve switching, solvent selection and cartridge exchange unit. When using SPE-LC with either APCI or PA-ESP, the detection limits of 15 (out of the 17) pesticides in tap water were 0.007-3 mu g/l in the full-scan and 0.1-200 ng/l in the SIM mode, with an analysis time of 65 min. Fenchlorphos and bromophos-ethyl could not be detected by either ionization method. APCI full-scan spectra showed much less sodium and acetonitrile/water cluster adducts than PA-ESP spectra. Negative ion (NI) operation was less sensitive for the majority of the compounds tested (73 in total), but several organophosphorus pesticides, nitrophenols and chlorophenols only gave a response in the NI mode. PA-ESP-MS-MS and APCI-MS-MS gave similar product-ion spectra from protonated molecules; an MS-MS library was built for more than 60 pesticides and their degradation products, at constant settings of collision gas pressure (argon, 2.0x10(-3) Torr) and collision energy (25 eV). The library was successfully used for searching product-ion spectra from SPE-LC-APCI-MS-MS at low levels (10 ng/l) in tap water and for the identification of atrazine in surface water (estimated concentration 0.25 mu g/l).
引用
收藏
页码:59 / 74
页数:16
相关论文
共 26 条
[1]   COMBINED LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY .3. APPLICATIONS OF THERMOSPRAY [J].
ARPINO, P .
MASS SPECTROMETRY REVIEWS, 1992, 11 (01) :3-40
[2]   LIQUID-CHROMATOGRAPHY - PARTICLE-BEAM MASS-SPECTROMETRY FOR IDENTIFICATION OF UNKNOWN POLLUTANTS IN WATER [J].
BAGHERI, H ;
SLOBODNIK, J ;
RECASENS, RMM ;
GHIJSEN, RT ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1993, 37 (3-4) :159-167
[3]   ONLINE LOW-LEVEL SCREENING OF POLAR PESTICIDES IN DRINKING AND SURFACE WATERS BY LIQUID-CHROMATOGRAPHY THERMOSPRAY MASS-SPECTROMETRY [J].
BAGHERI, H ;
BROUWER, ER ;
GHIJSEN, RT ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1993, 647 (01) :121-129
[4]   ENVIRONMENTAL-PROTECTION-AGENCY AND OTHER METHODS FOR THE DETERMINATION OF PRIORITY PESTICIDES AND THEIR TRANSFORMATION PRODUCTS IN WATER [J].
BARCELO, D .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :117-143
[6]   TRACE-LEVEL DETECTION AND IDENTIFICATION OF POLAR PESTICIDES IN SURFACE-WATER - THE SAMOS APPROACH [J].
BRINKMAN, UAT ;
SLOBODNIK, J ;
VREULS, JJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (09) :373-381
[9]   AUTOMATED ONLINE LIQUID-SOLID EXTRACTION FOLLOWED BY LIQUID CHROMATOGRAPHY-HIGH-FLOW PNEUMATICALLY ASSISTED ELECTROSPRAY MASS-SPECTROMETRY FOR THE DETERMINATION OF ACIDIC HERBICIDES IN ENVIRONMENTAL WATERS [J].
CHIRON, S ;
PAPILLOUD, S ;
HAERDI, W ;
BARCELO, D .
ANALYTICAL CHEMISTRY, 1995, 67 (09) :1637-1643
[10]   PARTICLE-BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - INSTRUMENTATION AND APPLICATIONS - A REVIEW [J].
CREASER, CS ;
STYGALL, JW .
ANALYST, 1993, 118 (12) :1467-1480