Dose perturbations at high-Z interfaces in kilovoltage photon beams:: comparison with Monte Carlo simulations and measurements

被引:20
作者
Das, IJ
Moskvin, VP
Kassaee, A
Tabata, T
Verhaegen, F
机构
[1] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
[2] Royal Marsden Hosp, Inst Canc Res, London SW3 6JJ, England
[3] Univ Osaka Prefecture, Sakai, Osaka 591, Japan
[4] Indiana Univ, Sch Med, Dept Radiat Oncol, Indianapolis, IN 46202 USA
关键词
interface dosimetry; dose perturbation; Monte Carlo; PENELOPE; high-Z; moving-window least-square polynomial fit;
D O I
10.1016/S0969-806X(01)00460-1
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dose perturbations, backscatter dose perturbation factor (BSDF), and forward dose perturbation factor (FDPF) near high-Z material interfaces have been reported to be intense and significant in kilovoltage photon beams. Validity of estimation of dose perturbations is critical in the evaluation of radiation effects associated with high-Z interfaces. The magnitude of dose perturbations has been debated due to limitations in the measuring devices (mainly window thickness and chamber perturbations). Monte Carlo (MC) simulations have been proposed for the interface effects but poor statistics in small spatial bins (1 mum) near the interface makes MC data questionable even with a well designed code. A moving-window least-square polynomial fit (MLPF) method is proposed to smooth MC simulated data. This method is shown to be useful in achieving reasonable accuracy from statistically poor MC data obtained within a reasonable computation time. The EGS4 and PENELOPE MC simulated data at the interfaces between high-Z materials and a water phantom have been used to calculate the BSDF and FDPF which differ significantly from the measurements suggesting the necessity of further refinements in MC approaches and better measuring devices at interface effects. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:173 / 179
页数:7
相关论文
共 24 条
[1]  
ADLER B, 1963, METHODS COMPUTATIONA
[2]   PENELOPE - AN ALGORITHM FOR MONTE-CARLO SIMULATION OF THE PENETRATION AND ENERGY-LOSS OF ELECTRONS AND POSITRONS IN MATTER [J].
BARO, J ;
SEMPAU, J ;
FERNANDEZVAREA, JM ;
SALVAT, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01) :31-46
[3]   Applicability of the condensed-random-walk Monte Carlo method at low energies in high-Z materials [J].
Berger, MJ .
RADIATION PHYSICS AND CHEMISTRY, 1998, 53 (03) :191-203
[4]   BACKSCATTER DOSE PERTURBATION IN KILOVOLTAGE PHOTON BEAMS AT HIGH ATOMIC-NUMBER INTERFACES [J].
DAS, IJ ;
CHOPRA, KL .
MEDICAL PHYSICS, 1995, 22 (06) :767-773
[5]   Forward dose perturbation at high atomic number interfaces in kilovoltage x-ray beams [J].
Das, IJ .
MEDICAL PHYSICS, 1997, 24 (11) :1781-1787
[6]  
DAS IJ, 1999, KILOVOLTAGE XRAY BEA, P239
[7]   Monte Carlo simulation of the inelastic scattering of electrons and positrons using optical-data models [J].
Fernandez-Varea, JM .
RADIATION PHYSICS AND CHEMISTRY, 1998, 53 (03) :235-245
[8]   Comparisons between MCNP, EGS4 and experiment for clinical electron beams [J].
Jeraj, R ;
Keall, PJ ;
Ostwald, PM .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (03) :705-717
[9]   Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version [J].
Kawrakow, I .
MEDICAL PHYSICS, 2000, 27 (03) :485-498
[10]   PARALLEL-PLATE IONIZATION-CHAMBER RESPONSE IN CO-60 IRRADIATED TRANSITION ZONES [J].
KOOY, HM ;
SIMPSON, LD ;
MCFAUL, JA .
MEDICAL PHYSICS, 1988, 15 (02) :199-203