Systems contributing to the assurance of transfusion safety in the United Kingdom

被引:10
作者
Williamson, LM [1 ]
机构
[1] Univ Cambridge, Div Transfus Med, E Anglia Ctr, Natl Blood Serv, Cambridge CB2 2PZ, England
关键词
D O I
10.1159/000031081
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In 1996, the United Kingdom launched a voluntary 'haemovigilance' system for confidential reporting of transfusion-related deaths and major adverse events. The Serious Hazards of Transfusion (SHOT) initiative provided the first comprehensive overview of transfusion safety in the UK, with 12 fatalities reported in the first year. The most important finding was that of a total of 169 reports, 47% were 'wrong blood to patient' episodes, of which 16 were ABO-incompatible, There were eight transfusion-transmitted infections, three bacterial, four viral and one malarial, A number of other initiatives exist in the UK which also have importance in contributing to transfusion safety. This article reviews these other key contributors, allowing SHOT to be context.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 14 条
[1]   Transfusion safety: realigning efforts with risks [J].
AuBuchon, JP ;
Kruskall, MS .
TRANSFUSION, 1997, 37 (11-12) :1211-1216
[2]  
*BLOOD GROUP SER S, 1996, UK NAT EXT QUAL ASS
[3]   Guidelines on gamma irradiation of blood components for the prevention of transfusion-associated graft-versus-host disease [J].
Chapman, J ;
Finney, RD ;
Forman, K ;
Kelsey, P ;
Knowles, SM ;
Napier, JAF ;
Phillips, P ;
Mitchell, R ;
Murphy, MF ;
Waters, AH ;
Wood, JK ;
Williamson, LM ;
Baglin, T ;
Copplestone, A ;
Dendy, P ;
Gibson, B ;
Knowles, S ;
Morgan, G ;
Norfolk, D ;
Richards, A ;
Todd, A ;
Warwick, R ;
Webb, D .
TRANSFUSION MEDICINE, 1996, 6 (03) :261-271
[4]  
CHAPMAN J, IN PRESS TRANSFUS ME
[5]  
*DEP HLTH, 1998, 1 CLASE SERV QUAL NE
[6]   Autologous donation error rates in Canada [J].
Goldman, M ;
RemyPrince, S ;
Trepanier, A ;
Decary, F .
TRANSFUSION, 1997, 37 (05) :523-527
[7]   Adherence to a strict specimen-labeling policy decreases the incidence of erroneous blood grouping of blood bank specimens [J].
Lumadue, JA ;
Boyd, JS ;
Ness, PM .
TRANSFUSION, 1997, 37 (11-12) :1169-1172
[8]  
Napier A, 1998, TRANSFUSION MED, V8, P59
[9]  
*RES UN ROYAL COLL, 1998, NAT AUD CLIN TRANSF
[10]   Activation of the contact system by filtration of platelet concentrates with a negatively charged white cell-removal filter and measurement of venous blood bradykinin level in patients who received filtered platelets [J].
Shiba, M ;
Tadokoro, K ;
Sawanobori, M ;
Nakajima, K ;
Suzuki, K ;
Juji, T .
TRANSFUSION, 1997, 37 (05) :457-462