Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes

被引:17
作者
Bencic, G. [1 ]
Vatavuk, Z. [1 ]
Marotti, M. [2 ]
Loncar, V. L. [1 ]
Petric, I. [1 ]
Andrijevic-Derk, B. [1 ]
Skunca, J. [1 ]
Mandic, Z. [1 ]
机构
[1] Univ Hosp Sestre Milosrdnice, Univ Dept Ophthalmol, Zagreb, Croatia
[2] Univ Hosp Sestre Milosrdnice, Univ Dept Radiol, Zagreb, Croatia
关键词
PARTIAL COHERENCE INTERFEROMETRY; RETINAL-DETACHMENT SURGERY; ULTRASOUND BIOMETRY; REMOVAL; PHACOEMULSIFICATION;
D O I
10.1136/bjo.2008.147868
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Aims: The aim of the study was to compare the accuracy of A-scan biometry and MRI for the measurement of axial length in silicone oil-filled eyes. Methods: This was a prospective randomised study of 70 patients. Biometry was performed using MRI in 33 patients (MRI group) and A-scan echography in 37 patients (A-scan group). The difference between predicted and final refraction was measured and evaluated statistically. Results: In patients with axial length >= 26 mm, the mean deviation of the final from predicted refraction was -1.23 (SD 0.67) D in the MRI group and -2.3 (SD 2.02) D in the A-scan group. The difference between these two groups was statistically significant (p = 0.02). In patients with axial length,26 mm, the mean deviation of the final from predicted refraction was -0.12 (SD 1.29) D in the MRI group and -0.33 (SD 1.39) D in the A-scan group. There was no statistical significance between the two groups (p = 0.629). Conclusion: For highly myopic patients MRI biometry was a more accurate measurement of axial length in silicone oil-filled eyes. A-scan and MRI biometry were comparably accurate in measuring axial length in patients with axial length <26 mm.
引用
收藏
页码:502 / 505
页数:4
相关论文
共 25 条
[1]
ALTMAN DG, 2000, PRACTICAL STAT MED R, P456
[2]
Combined phacoemulsification and transpupillary drainage of silicone oil: results and complications [J].
Assi, A ;
Woodruff, S ;
Gotzaridis, E ;
Bunce, C ;
Sullivan, P .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (08) :942-945
[3]
BAER RM, 1995, EYE, V70, P382
[4]
BROURMAN ND, 1989, OPHTHALMOLOGY, V96, P759
[5]
BYRNE SF, 1995, A SCAN AXIAL EYE LEN
[6]
CIBIS PA, 1962, ARCH OPHTHALMOL-CHIC, V68, P590
[7]
Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal [J].
El-Baha, SM ;
El-Samadoni, A ;
Idris, HF ;
Rashad, KM .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (07) :622-626
[8]
Findl O, 2002, DEV OPHTHALMOL, V34, P131
[9]
Frau E, 1999, BRIT J OPHTHALMOL, V83, P1406
[10]
The problems of biometry in combined silicone oil removal and cataract extraction - A clinical trial [J].
Ghoraba, HH ;
El-Dorghamy, AA ;
Atia, AF ;
Yassin, ABDEAI .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (05) :589-596