Treatment of IGCC power station effluents by physico-chemical and advanced oxidation processes

被引:9
作者
Duran, A. [1 ]
Monteagudo, J. M. [1 ]
Sanmartin, I. [1 ]
Garcia-Pena, F. [2 ]
Coca, P. [2 ]
机构
[1] Univ Castilla La Mancha, Escuela Tecn Super Ingenieros Ind, Dept Chem Engn, E-13071 Ciudad Real, Spain
[2] CT GICC Puertollano, Elcogas SA, Ciudad Real 13500, Spain
关键词
Cu(II); Photocatalysis; Wastewater; WASTE-WATER; CYANIDE; DESTRUCTION; DEGRADATION; PHOTODEGRADATION;
D O I
10.1016/j.jenvman.2008.08.002
中图分类号
X [环境科学、安全科学];
学科分类号
083001 [环境科学];
摘要
The aim of this work was to improve the quality of aqueous effluents coming from the Gasification Unit in an Integrated Gasification Combined Cycle (IGCC) Thermoelectric Power Station, with the purpose of fulfilling the future more demanding normative. To this end, an integral wastewater treatment including coagulation, flocculation, neutralization, photocatalytic oxidation, and ion-exchange has been studied. A final scheme has been proposed to remove pollutants. All the parameters of the treated wastewater are below pouring specifications. In the first stage, the wastewater was treated with CaCl2 (optimal dose = 11 g CaCl2/g F-) as coagulant and a commercial anionic polyelectrolyte (optimal dose = 0.02 g/g F-) as flocculant to remove fluoride ions (99%) and suspended solids (92%). The water was then neutralized, improving the degree of transmission of ultraviolet light, allowing the faster photo-degradation of pollutants. The photochemical study included different systems (H2O2, UV/H2O2, Fenton, Fenton-like, UV/Fenton, UV/Fenton-like and UV/H2O2/O-2). In the Fenton-like system, the influence of two parameters (initial concentration of H2O2 and amount of Cu(II)) on the degradation of cyanide and formate (taken as the reference of the process) was studied. Experimental results were fit using neural networks (NNs). Results showed that the photocatalytic process was effective for total cyanide destruction after 60 min, while 180 min was needed to remove 80% of formates. However, a more simple system with UV/H2O2/O-2 yields similar results and is preferred for industrial application due to fewer complications. Finally, an ion-exchange process with Amberlite IRA-420 was proposed to remove the excess of chlorides added as a consequence of the initial coagulation process. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1370 / 1376
页数:7
相关论文
共 18 条
[1]
[Anonymous], 1995, Standard methods for examination of water and waste water, V19th
[2]
Augugliaro V, 1999, FRESEN ENVIRON BULL, V8, P350
[3]
Effects of single and combined ozonation with hydrogen peroxide or UV radiation on the chemical degradation and biodegradability of debittering table olive industrial wastewaters [J].
Beltrán, FJ ;
García-Araya, JF ;
Frades, J ;
Alvarez, P ;
Gimeno, O .
WATER RESEARCH, 1999, 33 (03) :723-732
[4]
Benitez FJ, 1997, J CHEM TECHNOL BIOT, V70, P253, DOI 10.1002/(SICI)1097-4660(199711)70:3<253::AID-JCTB770>3.3.CO
[5]
2-8
[6]
Box G.E., 1978, STAT EXPT
[7]
Neural networks simulation of photo-Fenton degradation of Reactive Blue 4 [J].
Duran, A. ;
Monteagudo, J. M. ;
Mohedano, M. .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2006, 65 (1-2) :127-134
[8]
Degradation of BTEX and PAHs by Co(II) and Cu(II)-based radical-generating systems [J].
Gabriel, J ;
Baldrian, P ;
Verma, P ;
Cajthaml, T ;
Merhautová, V ;
Eichlerová, I ;
Stoytchev, I ;
Trnka, T ;
Stopka, P ;
Nerud, F .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2004, 51 (03) :159-164
[9]
Chemical reactions at low pressures [J].
Langmuir, I .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1915, 37 :1139-1167
[10]
Oxidative treatment of cyanide in wastewater using hydrogen peroxide and homogeneous catalyst [J].
Lee, TY ;
Kwon, YS ;
Kim, DS .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2004, 39 (03) :787-801