Sensitive fluorescent detection of protein on nylon membranes

被引:12
作者
Dubitsky, A
DeCollibus, D
Ortolano, GA
机构
[1] Pall Corp, Sci Serv, E Hills, NY USA
[2] Pall Corp, Lab Serv, E Hills, NY USA
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 2002年 / 51卷 / 01期
关键词
fluorescent; membrane; protein; arrays; western;
D O I
10.1016/S0165-022X(01)00243-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Detection of antigen immobilized on membranes, as in Western transfers and dot enzyme linked immunosorbent assays (ELISAs), often employ antibody-enzyme conjugates and chemiluminescent or precipitated colored reaction products. Although chemiluminescent markers are sensitive, they are time-consuming because of their required exposure to X-ray film and the presence of background artifacts sometimes limits their use. This report demonstrates that direct fluorescent detection technique using nylon membranes that has higher sensitivity than chemiluminescent methods is easier to perform and has a uniform, low background. An alkaline phosphatase conjugated antibody was compared with antibody conjugated to a fluorescent phycobiliprotein (allophycocyanin) for sensitivity in both Western transfers and dot ELISA assays using mouse IgG as the membrane-bound antigen. Direct fluorescent detection of antigen-antibody complexes on positively charged nylon membrane provided better sensitivity and lower background than similar conditions using enzyme amplification and chemiluminescent detection on either nylon or PVDF membranes. Processing time was reduced by the elimination of steps associated with substrate incubation, washing and X-ray film exposures required for chemiluminescence detection. These data support the view that direct fluorescent detection can represent a significant improvement in assay sensitivity and reduction in time compared with more traditional chemiluminescent detection techniques employed in the conduct of Western transfers and dot ELISA studies. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 11 条
[1]   Rapid fluorescent monitoring of total protein patterns on sodium dodecyl sulfate-polyacrylamide gels and Western blots before immunodetection and sequencing [J].
Alba, FJ ;
Daban, JR .
ELECTROPHORESIS, 1998, 19 (14) :2407-2411
[2]   A RAPID AND SENSITIVE CHEMILUMINESCENCE DOT-IMMUNOBINDING ASSAY FOR SCREENING HYBRIDOMA SUPERNATANTS [J].
BAKKALI, L ;
GUILLOU, R ;
GONZAGUE, M ;
CRUCIERE, C .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 170 (02) :177-184
[3]   Profiling expression patterns and isolating differentially expressed genes by cDNA microarray system with colorimetry detection [J].
Chen, JJW ;
Wu, R ;
Yang, PC ;
Huang, JY ;
Sher, YP ;
Han, MH ;
Kao, WC ;
Lee, PJ ;
Chiu, TF ;
Chang, F ;
Chu, YW ;
Wu, CW ;
Peck, K .
GENOMICS, 1998, 51 (03) :313-324
[4]  
EGGER D, 1994, MOL BIOTECHNOL, V3, P289
[5]   Development, characterisation and diagnostic application of monoclonal antibodies against Yersinia pestis fibrinolysin and coagulase [J].
Feodorova, VA ;
Devdariani, ZL .
JOURNAL OF MEDICAL MICROBIOLOGY, 2000, 49 (03) :261-269
[6]   High resolution autoantibody detection by optimized protein G-horseradish peroxidase immunostaining in a Western blotting assay [J].
Hu, GR ;
Harrop, P ;
Warlow, RS ;
Gacis, ML ;
Walls, RS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 202 (02) :113-121
[7]   Sensitive assays for isolation and detection of simian foamy retroviruses [J].
Khan, AS ;
Sears, JF ;
Muller, J ;
Galvin, TA ;
Shahabuddin, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (08) :2678-2686
[8]   Etiology of genital ulcer disease and its relationship to HIV infection [J].
Morse, SA .
SEXUALLY TRANSMITTED DISEASES, 1999, 26 (01) :63-65
[9]  
Patton WF, 2000, ELECTROPHORESIS, V21, P1123, DOI 10.1002/(SICI)1522-2683(20000401)21:6<1123::AID-ELPS1123>3.3.CO
[10]  
2-5