New sonographic criteria for recommending fine-needle aspiration biopsy of nonpalpable solid nodules of the thyroid

被引:769
作者
Kim, EK
Park, CS
Chung, WY
Oh, KK
Kim, DI
Lee, JT
Yoo, HS
机构
[1] Yonsei Univ, Coll Med, Severance Hosp,Res Inst Radiol Sci, Dept Diagnost Radiol,Seodaemun Gu, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Hosp, Dept Gen Surg, Seoul 120752, South Korea
关键词
D O I
10.2214/ajr.178.3.1780687
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to provide new sonographic criteria for fine-needle aspiration biopsy of nonpalpable solid thyroid nodules. MATERIALS AND METHODS. Sonographic scans of 155 nonpalpable thyroid nodules in 132 patients were prospectively classified as having positive or negative findings. Sono-graphic findings that suggested malignancy included microcalcifications, an irregular or microlobulated margin, marked hypoechogenicity, and a shape that was more tall than it was wide. even one of these sonographic features was present, die nodule was classified as positive (malignant). If a nodule had none of the features described, it was classified as negative (benign). final diagnosis of a lesion as benign (n = 106) or malignant (n = 49) was confirmed by fine-aspiration biopsy and follow-up (>6 months) in 83 benign nodules, by fine-needle aspiration biopsy and surgery in 44 malignant and 15 benign lesions, and by surgery alone in five malignant and eight benign lesions. The sensitivity, specificity, positive predictive value, negative value, and accuracy were calculated on the basis of our proposed classification method. RESULTS. Of 82 lesions classified as positive, 46 were malignant. Of 73 lesions classified negative, three were malignant. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy based on our sonographic classification method were 93.8%, 66%, 56.1%, 95.9%, and 74.8%, respectively. CONCLUSION. Considering the high level of sensitivity of our proposed sonographic fine-needle aspiration biopsy should be performed on thyroid nodules classified positive, regardless of palpability.
引用
收藏
页码:687 / 691
页数:5
相关论文
共 20 条
  • [1] THYROID-GLAND - ULTRASOUND SCREENING IN A RANDOM ADULT-POPULATION
    BRANDER, A
    VIIKINKOSKI, P
    NICKELS, J
    KIVISAARI, L
    [J]. RADIOLOGY, 1991, 181 (03) : 683 - 687
  • [2] Importance of thyroid abnormalities detected at US screening: A 5-year follow-up
    Brander, AEE
    Viikinkoski, VP
    Nickels, JI
    Kivisaari, LM
    [J]. RADIOLOGY, 2000, 215 (03) : 801 - 806
  • [3] ULTRASONIC EVALUATION OF BENIGN AND MALIGNANT NODULES IN ECHOGRAPHICALLY MULTINODULAR THYROIDS
    BRKLJACIC, B
    CUK, V
    BENCEZIGMAN, Z
    DELICBRKLJACIC, D
    DRINKOVIC, I
    TOMICBRZAC, H
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 1994, 22 (02) : 71 - 76
  • [4] EZZAT S, 1994, ARCH INTERN MED, V154, P1838
  • [5] FIBROADENOMA OF THE BREAST - SONOGRAPHIC APPEARANCE
    FORNAGE, BD
    LORIGAN, JG
    ANDRY, E
    [J]. RADIOLOGY, 1989, 172 (03) : 671 - 675
  • [6] FORNAGE BD, 1990, J ULTRAS MED, V9, P559
  • [7] HARACH HR, 1985, CANCER-AM CANCER SOC, V56, P531, DOI 10.1002/1097-0142(19850801)56:3<531::AID-CNCR2820560321>3.0.CO
  • [8] 2-3
  • [9] THYROID-NODULES - SONOGRAPHIC-PATHOLOGIC CORRELATION
    KATZ, JF
    KANE, RA
    REYES, J
    CLARKE, MP
    HILL, TC
    [J]. RADIOLOGY, 1984, 151 (03) : 741 - 745
  • [10] FATE OF UNTREATED BENIGN THYROID-NODULES - RESULTS OF LONG-TERM FOLLOW-UP
    KUMA, K
    MATSUZUKA, F
    YOKOZAWA, T
    MIYAUCHI, A
    SUGAWARA, M
    [J]. WORLD JOURNAL OF SURGERY, 1994, 18 (04) : 495 - 499