Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle

被引:85
作者
Bloomer, TN [1 ]
Plein, S [1 ]
Radjenovic, A [1 ]
Higgins, DM [1 ]
Jones, TR [1 ]
Ridgway, JP [1 ]
Sivananthan, MU [1 ]
机构
[1] Gen Infirm, British Heart Fdn, Cardiac MRI Unit, Leeds LS1 3EX, W Yorkshire, England
关键词
steady state free precession; ventricular function; radial long axis; magnetic resonance imaging; turbo gradient echo;
D O I
10.1002/jmri.10019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study we assessed the use of a steady state free precession (SSFP) cine sequence in a series of radially orientated long axis slices for the measurement of left ventricular volumes and mass. We validated the radial long axis approach in phantoms and ex vivo porcine hearts and applied it to normal volunteers and patients using the SSFP and turbo gradient-echo (TGE) sequences. High quality images were obtained for analysis, and the measured volumes with radial long axis SSFP sequence correlated well with short axis TGE and SSFP volumes (r > 0.98). The best interobserver agreement for left ventricular volumes was obtained using SSFP in the long axis radial orientation (variability < 2.3%). We conclude that this combination of sequence and scan orientation has intrinsic advantages for image analysis due to the improved contrast and the avoidance of errors associated with the basal slice in the short axis orientation. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:685 / 692
页数:8
相关论文
共 32 条
[1]  
AGNOSTOPOULOS C, 1998, NUC MED COMMUN, V19, P435
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Global cardiac function using fast breath-hold MRI: Validation of new acquisition and analysis techniques [J].
Bloomgarden, DC ;
Fayad, ZA ;
Ferrari, VA ;
Chin, B ;
Sutton, MGSJ ;
Axel, L .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :683-692
[4]  
Buck T, 1997, CIRCULATION, V96, P4286
[5]   NONINVASIVE EVALUATION OF GLOBAL LEFT-VENTRICULAR FUNCTION WITH USE OF CINE NUCLEAR MAGNETIC-RESONANCE [J].
BUSER, PT ;
AUFFERMANN, W ;
HOLT, WW ;
WAGNER, S ;
KIRCHER, B ;
WOLFE, C ;
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1294-1300
[6]  
Cwajg E, 1999, J NUCL MED, V40, P1857
[7]   Relation between the number of image planes and the accuracy of three-dimensional echocardiography for measuring left ventricular volumes and ejection fraction [J].
Danias, PG ;
Chuang, ML ;
Parker, RA ;
Beaudin, RA ;
Mooney, MG ;
Manning, WJ ;
Douglas, PS ;
Hibberd, MG .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (11) :1431-+
[8]   QUANTIFICATION OF THE LEFT-VENTRICULAR VOLUMES AND FUNCTION WITH CINE MR-IMAGING - COMPARISON OF GEOMETRIC-MODELS WITH 3-DIMENSIONAL DATA [J].
DULCE, MC ;
MOSTBECK, GH ;
FRIESE, KK ;
CAPUTO, GR ;
HIGGINS, CB .
RADIOLOGY, 1993, 188 (02) :371-376
[9]  
Faber TL, 1999, J NUCL MED, V40, P650
[10]   DETERMINATION OF LEFT-VENTRICULAR VOLUME BY 2-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON WITH MAGNETIC-RESONANCE-IMAGING [J].
HERREGODS, MC ;
DEPAEP, G ;
BIJNENS, B ;
BOGAERT, JG ;
RADEMAKERS, FE ;
BOSMANS, HT ;
BELLON, EP ;
MARCHAL, GJ ;
BAERT, AL ;
VANDEWERF, F ;
DEGEEST, H .
EUROPEAN HEART JOURNAL, 1994, 15 (08) :1070-1073